beautypg.com

Important safety requirements, Instructions for the installer, Provision for ventilation – Electrolux EK 5731 User Manual

Page 18: Dimensions, Technical data, Oven, Location, Positioning the cooker

background image

18

Important Safety Requirements

This appliance must be installed in accordance

with the Gas Safety (Installation and Use)

Regulations (current addition) and the I.E.E.

Wiring Regulations. Detailed recommendations

are contained in the following British Standard

Codes of Practice - B.S. 6172, B.S. 5440: Part 2

and B.S. 6891: Current Editions.

Provision for Ventilation

The room containing the cooker should have an

air supply in accordance with B.S. 5440: Part 2:

Current Editions.

The following requirements for ventilation must

be met.

The cooker should not be installed in a bed

sitting room with a volume of less than 20m

3

, if it

is installed in a room of volume less 5m

3

an air

vent of effective area of 110cm

2

is required; if it

is installed in a room of volume between 5m

3

and 10m

3

, an air vent of effective area 50cm

2

is

required, while if the volume exceeds 11m

3

no

air vent is required. However, if the room has a

door which opens directly to the outside, no air

vent is required even when the volume is

between 5m

3

and 11m

3

.

If there are other fuel burning appliances in the

same room, B.S. 5440: Part. 2: Current Editions

should be consulted to determine the requisite

air vent requirements.

Model Number:

EK 5731

Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY:

II

2H3+

APPLIANCE GAS SUPPLY: Natural gas G20

20mbar

Dimensions

Height

900 mm

Depth

600 mm

Width

499 mm

Oven Capacity

1.7 Cu. ft

Technical Data

Instructions for the Installer

Hob

Rear left burner (rapid)

3,000 W

Front left burner (semi-rapid)

2,000 W

Rear right burner (semi-rapid)

2,000 W

Front right burner (auxiliary)

1,000 W

Oven

Top heating element

1,044 W

Bottom heating element

1,252 W

Grill Element

1,879 W

Oven light

15 W

Total rating

2,311 W

Supply voltage (50 Hz)

230-240 V

Location

The cooker may be located in a kitchen, a

kitchen/diner or bedsitting room but not in a

bathroom, shower room or garage.

For information regarding the fitting of flexible

supply pipes, the highest temperature at the rear

of this cooker which may come into contact with

the supply pipe is 70°C above ambient.

When the appliance has been installed there

must be enough space fot the hotplate lid (when

present) to open fully.

Positioning the Cooker

Caution:
Some soft or badly fitted floor coverings can be

damaged when the cooker is moved across

their surface for cleaning. It is advisable to

ensure that the floor covering in the area below

the cooker is either securely fixed so as not to

ruck up when the cooker is moved or, if

preferred, removed.