13. TROUBLESHOOTING

14. SPECIFICATIONS

4.18'

13.30

kgs

15.50

kgs

RPM

CFM

N.W.

G.W.

C.F.

120

120

120

Fan Size

52"

Speed

Volts

Amps

Watts

Low

Medium

High

These are approximate measures. They do not include Amps and Wattage used by the light kit.

Problem

Fan will not start.

Fan sounds noisy.

Fan wobble.

Remote control

malfunction.

Solution

1. Check circuit fuses or breakers.

2. Check line wire connections to the fan and switch wire connections in the

switch housing. CAUTION: Make sure main power is off.

3. Check to make sure the dip switches from the transmitter and receiver are

set to the same frequency.

1. Make sure all motor housing screws are snug.

2. Make sure the screws that attach the fan blade bracket to the motor hub is

tight.

3. Make sure wire nut connections are not rubbing against each other or the

interior wall of the switch housing. CAUTION: Make sure main power is off.

4. Allow a 24-hour "breaking-in" period. Most noise associated with a new fan

disappear during this time.

5. If using an optional light kit, make sure the screws securing the glassware

are tight. Check that light bulb is also secure.

6. Do not connect the fan with wall mounted variable speed control(s).

7. Make sure the upper canopy is a short distance from the ceiling. It should

not touch the ceiling.

1. Check that all blade and blade arm screws are secure.

2. Most fan wobbling problems are caused when blade levels are unequal.

Check this level by selecting a point on the ceiling above the tip of one of the

blades. Measure this distance. Rotate the fan until the next blade is

positioned for measurement. Repeat for each blade. The distance deviation

should be equal within 1/8".

3. Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable.

4. If the blade wobble is still noticeable, interchanging two adjacent (side by

side) blades can redistribute the weight and possibly result in smoother

operation.

1. Do not connect the fan with wall mounted variable speed control(s).

2. Make sure the dip switches are set correctly.

4. Check to make sure the batteries are installed porperly. ( postive +side

facing out)

5 . Check to make sure the batteries are not dead.

0.68
0.43
0.23

82
31

9

175
108

56

6790
3618
1712

9