beautypg.com

Technical details – Electrolux EKG6046/EKG6047 User Manual

Page 30

background image

30

TECHNICAL DETAILS

DIMENSIONS


Height:

900

mm

(nominal)

Width:

600

mm

(nominal)

Depth:

600 mm (to front of door panel)

Weight:

66

Kg Net


Space for fixing at hotplate level 2mm minimum clearance
Space for fixing above hotplate level See important note 'Location of Appliance'.
Minimum space above hotplate 750mm (If cooker hood is fitted refer to the cooker hood installation instructions.

Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel)


CONNECTIONS


Gas connection: -

Rear left hand side of appliance at hotplate level
Rc ½ (½” B.S.P. female)


Electrical connection: -

230 - 240 V 50 Hz Mains connected at rear centre of appliance using at
least 2.5mm

2

multi core PVC insulated cable.


HOTPLATE

Natural Gas

Heat

Input

R.H.F

R.H.F

L.H.R

L.H.F

1.0kW

1.9kW 1.9kW

3.0kW

(3412 Btu/h)

(6483 Btu/h)

(6483 Btu/h)

(10236 Btu/h)

Injector

Marking

070

096

096

119

L.P.Gas

Heat

Input

1.0kW

2.0kW

2.0kW

2.8kW

(71.8g/h)

(143.6g/h)

(143.6g/h)

(194.0g/h)

Injector

Marking

050

071

071

086


GRILL

Natural Gas

L.P.Gas

Heat

Input

2.7kW

(9212 Btu/h)

2.7kW (194g/h)

Injector Marking

120

95


SECOND OVEN

Heat

Input

1.9kW

(6483 Btu/h)

1.9kW (136.5g/h)

Injector Marking

099

070

Dual

Control

By-Pass

50

38


MAIN OVEN

Heat

Input

1.9kW

(6483 Btu/h)

1.9kW (136.5g/h)

Injector Marking

099

070

Thermostat

By-Pass

Marking

75

80


GENERAL

Ignition

(H.T.

Spark)

Spark

Gap

3-4mm


GAS CATEGORY COUNTRIES OF DESTINATION

CAT. I

2H

GB

CAT. I

3+

GB

This appliance complies with: European Council Directives Low voltage Directive
73/23/EEC ,Gas Directive 90/396/EEC EMC Directive 89/336/EEC, CE Marking
Directive 93/68/EEC.