Caution, Model 1000 suitable for use in mobile homes, Made in canada – Enviro ENVIROFIRE 1600 User Manual
Page 16
DO NOT REMOVE THIS LABEL
WH-
LISTED SOLID FUEL SPACE HEATER SERIAL NO.
MODEL:
1000
1600
2100 1600 INS
MODEL 1000 SUITABLE FOR USE IN MOBILE HOMES.
CERTIFIED FOR CANADA AND THE U.S.A. REPORT NO. J99011443-231
TESTED TO CSA B366.2/ULC-S627, ULC-S628-M93, UL-1482-1994
REPORT NO. 6385
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURERS INSTALLATION AND OPERATING INSTRUCTIONS. CONTACT LOCAL
BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. USE 6 IN. / 150 MM DIAMETER
MINIMUM 24 MSG BLACK OR 25 MSG BLUED STEEL CONNECTOR LISTED FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS
OR MASONRY CHIMNEY. SEE LOCAL BUILDING CODE AND MANUFACTURER’S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING
A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR
CEILING. MINIMUM CLEARANCES FROM HORIZONTAL CONNECTOR AND CEILING (18 IN./ 455 MM) DO NOT CONNECT THIS UNIT TO A
CHIMNEY FLUE SERVICING ANOTHER APPLIANCE U.S.A. ONLY.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
RESIDENTIAL INSTALLATIONS USING SINGLE WALL CONNECTOR. WITH ANY ULC-S629 LISTED CHIMNEY IN CANADA , AND
ANY UL 103 HT LISTED CHIMNEY SYSTEMS IN THE U.S.A.
MODEL :1000
MODEL: 1600
MODEL: 2100
SIDE WALL TO UNIT A
BACK WALL TO UNIT B
CORNER TO UNIT C
SIDE WALL TO CONNECTOR D
BACK WALL TO CONNECTOR E
CORNER TO CONNECTOR F
19 IN. / 485 MM
10 IN. / 255 MM
6 IN. / 150 MM
28 IN. / 710 MM
13 IN. / 330 MM
16 IN. / 405 MM
20 IN. / 510 MM
12 IN. / 305 MM
6 IN. / 150 MM
29 IN. / 735 MM
16.5 IN. / 420 MM
16.5 IN. / /420 MM
22 IN. / 560 MM
12 IN. / 305 MM
8 IN. / 205 MM
31 IN. / 790 MM
16.5 IN. / 420 MM
19 IN. / 485 MM
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATIONS: MODELS 1000 AND 1600
IN CANADA: ANY ULC-629 LISTED CHIMNEY SYSTEM WITH THE ACCOMPANYING DOUBLE WALL VENT CONNECTOR
IN U.S.A.: ANY HT-103 LISTED CHIMNEY SYSTEM WITH THE ACCOMPANYING DOUBLE WALL VENT CONNECTOR
SPECIFIED CLEARANCES APPLY AND UNITS MAY BE INSTALLED IN CONVENTIONAL HOMES IF SPECIFIED CONNECTORS ARE USED.
MODEL 1000
MODEL 1600
SIDE WALL TO UNIT A
BACK WALL TO UNIT B
CORNER TO UNIT C
SIDE WALL TO CONNECTOR D
BACK WALL TO CONNECTOR E
CORNER TO CONNECTOR F
14 IN./ 355 MM
6 IN. / 150 MM
2 IN. / 50 MM
23 IN. / 585 MM
9 IN. / 230 MM
11.5 IN. / 290 MM
11 IN. / 280 MM
4 IN. / 101 MM
6 IN. / 153 MM
20 IN. / 508 MM
8.25 IN. / 210 MM
15.5 IN. / 394 MM
MODEL 1000 MAY BE INSTALLED IN AN ALCOVE: ALCOVE DEPTH, 4 FT. /1.22 M, HEIGHT 7 FT. 2.13 M
MODEL 1600 MAY BE INSTALLED IN AN ALCOVE: ALCOVE DEPTH 30” (76 CM) HEIGHT 70”(178 CM) WIDTH 48” (122 CM)
ROOM HEATER, SOLID FUEL TYPE, SUITABLE FOR MOBILE HOMES
If a stove is installed on a combustible floor, it must have a
pedestal attached and be on a NON COMBUSTIBLE hearth pad
extending at least 8” (200 mm) to each side, and 18” (455 mm)
to the front
MODEL 1600 INS MAY BE INSTALLED AS AN INSERT IN A MASONRY
FIREPLACE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURE TO UNIT)
MODEL 1600 INS
ADJACENT SIDE WALL A
MANTLE B
TOP FACING C
SIDE FACING D
17 IN. / 430 MM
28 IN. / 710 MM
28 IN. / 710 MM
1 IN. / 25 MM
HEARTH EXTENSION MUST BE RAISED (F) 8 IN. / 205 MM ABOVE A SURROUNDING COMBUSTIBLE FLOOR.
COMBUSTIBLE FLOOR MUST BE PROTECTED BY A NON-COMBUSTIBLE MATERIAL EXTENDING (E) 18 IN.
455 MM TO THE FRONT OF THE UNIT AND (F) 8 IN. / 205 MM TO THE SIDES
OPERATE ONLY WITH THE DOOR AND ASH PAN CLOSED. ONLY OPEN DOOR TO FEED FIRE. FOR USE WITH SOLID WOOD FUELS ONLY. DO NOT
USE GRATE OR ELEVATE-FIRE BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE, DO NOT OBSTRUCT COMBUSTION AIR
OPENINGS.. IF HEATER OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY FREQUENTLY-UNDER
CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHING AND OTHER COMBUSTIBLES WELL AWAY
FROM HEATER. REPLACE GLASS ONLY WITH CERAMIC GLASS. OPTIONAL COMPONENTS: FAN, ELECTRICAL RATING 115V, 60 Hz 1 AMP.
ROUTE CORD AWAY FROM HEATER.
MANUFACTURED BY:
SHERWOOD INDUSTRIES LTD.
6782 OLDFIELD RD.
VICTORIA B.C V8M-2A3
MADE IN CANADA
CAUTION
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURN. READ NAMEPLATE AND INSTRUCTIONS.
16