Blow function
Connect the hose directly to the blow outlet of the vacuum cleaner.
Emptying the tub
Switch off and unplug the machine.
Remove the motor housing (2).
Empty the tub (5).
9 CLEANING AND MAINTENANCE
Attention ! Before performing any work on the equipment, pull the power
plug.
Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
Do not submerge the motor housing in water!
Cleaning the tub
Empty and clean the tub (5) after each use.
Dry the tub carefully after the machine has been used for vacuuming up liquids.
Cleaning the dust filter( FIG C)
Shake out the dust from the dust filter after each use.
Remove mesh and clean it carefully.
10 TECHNICAL DATA
POWX320
Mains Voltage
220-240V
Frequency
50 Hz
Power input
800 W
Tub capacity
10 l
Weight
4,5 kg
11 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a special
connecting cable which is available from our service department. Replacement of the
connecting cable should only be carried out by our service department (see last page) or
by a specialist (qualified electrician).