SOUND EMISSION
Noise emission values measured according to relevant standard.
LpA Sound pressure level
99.6 dB(A)
LwA Sound power level
112,6 dB(A)
ATTENTION ! The sound power pressure may exceed 85 dB(A), in this case
individual hearing protection must be worn.
12 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by a
qualified person (qualified electrician).
13 STORAGE
Thoroughly clean the whole machine and its accessories.
Store it out of the reach of children, in a stable and secure position, in a cool and dry place,
avoid too high and too low temperatures.
Protect it from exposure to direct sunlight. Keep it in the dark, if possible.
Don’t keep it in plastic bags to avoid humidity build-up.
14 TROUBLE SHOOTING
PROBLEM
ACTION
The machine does not start
1) Check that it is properly plugged into the outlet.
The machine stops itself
1) Press the Reset button and wait several minutes
(thermal breaker).
2) Check that the chip extraction ports are not
obstructed.
The machine does not turn at full
power
1) Decrease the depth of the cut.
2) Check the status of the blades.
3) Check the carbon brushes
4) Check the in feed belt located under the black
metal cover.
The cuts are not clean
1) Check the status of the blades
2) Check the alignment of the blades.
3) Plane the wood with the grain
The machine is not properly
extracting the chips.
1) Check that the extraction ports are not clogged