Checking and cleaning the air filter, Trouble-shooting, Engine does not start – Powerplus POWX1770 COMPRESSOR 2200W 50L LUBRICATED EN User Manual
Page 9: Compressor does not supply air, Pressure is too high, Technical details, Noise
POWX1770
EN
Copyright © 2014 VARO
P a g e
| 9
www.varo.com
8.6
Checking and cleaning the air filter
Check the air filter every 3 months.
Let the machine cool down.
Pull the air filter cap from the filter.
Clean the filter with dry air. If necessary
replace the filter.
Pull the air filter cap back into the filter.
9 TROUBLE-SHOOTING
If the machine does not work correctly, follow the directions below to solve the problem. If you
can’t solve the problem yourself, contact your dealer.
9.1
Engine does not start
Check that the on/off switch is in the "ON" position.
Check that the power supply corresponds to the voltage on the rating plate of the
machine.
Check that the fuses in the meter cupboard are intact.
Check that no extension cords are used that do not comply with the applicable regulations.
Check that the work environment is not too cold.
9.2
Compressor does not supply air
Check that the pressure regulator is adjusted correctly.
9.3
Pressure is too high
Check if the hose is connected to the correct valve.
Re-adjust the pressure.
10 TECHNICAL DETAILS
Rated voltage
220-240 V~
Rated frequency
50 Hz
Rated Power
2200 W / 3 pk
Rotation speed
2850 min-1
Rated Pressure
9 bar / 131 PSI
Tank capacity
50 l
Air debit (capacity)
356 l/min
Weight
45 kg
Cylinder
2
Lubricated
Yes
11 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
77 dB(A)
Acoustic power level LwA
97 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).