Instructions for use, Switching on and off, Cleaning and maintenance – Powerplus POWX1770 COMPRESSOR 2200W 50L LUBRICATED EN User Manual
Page 7: Venting and bleeding the tank, Changing the oil
POWX1770
EN
Copyright © 2014 VARO
P a g e
| 7
www.varo.com
Never exceed the maximum operating pressure of the equipment
connected.
7.4
Instructions for use
Check if the tank is vented and bled.
Check the oil-level.
Check the operation of the safety valve.
Check whether the air hose is connected properly.
Switch on the machine and allow the pressure in the tank to build up.
As soon as the tank pressure is built up, the motor switches off automatically.
The motor switches automatically on as soon as the tank pressure becomes too low.
After use, switch off the machine. Vent the tank and bleed the moisture collected in the
tank.
7.5
Switching on and off
To switch on the machine, pull the on/off switch.
To switch off the machine, press the on/ off
switch.
8 CLEANING AND MAINTENANCE
Clean the outside of the machine with a moist cloth.
Regularly check the machine for possible damages and leakage.
8.1
Venting and bleeding the tank
After each use the tank must be vented and the moist collected in the tank must be drained.
Turn the machine backwards to gain access to the water outlet valve.
Loosen the screw carefully in such a way that the tank is vented fluently.
Turn the machine forward en let the moist flow from the tank. Move the tank a few times
so that all moist can flow from the tank.
Tighten the screw securely.
Always make sure that all the moist has been drained from the tank. Never
fully close the water outlet valve if you leave the machine in an area colder
than 0 °C.
8.2
Changing the oil
The oil in the pump must be changed after the first 50 operating hours, and then after every
200 hours or 3 months,