Measure the amount of time it takes for the cup to empty back into the can. The table below
shows recommended times for different types of material.
VISCOSITY TABLE

Varnishes, synthetic resin primers

Undiluted

– 30

Synthetic resin paints, clear varnishes

15-30

Acrylic paints

20-30

Wood preservative, pesticides, oils

Undiluted (max.30)

Aluminium paints

15-30

Disinfectants, cleaning agents, polishes

Undiluted (max.30)

8

CLEANING AND MAINTENANCE

Always remember to disconnect from the mains supply before cleaning the
spray gun or paint container.

It is very important to clean your spray gun thoroughly after use. Failure to do so may render
the spray gun useless. Clean using suitable thinners, turpentine or water, depending on the
product used for spraying. Never immerse the spray gun in any fluid. Use tinners, turpentine or
water with a cloth to clean the exterior of the spray gun and a small brush for the spray
assembly. If the cylinder hole becomes blocked, use a suitable cylinder cleaning needle (not
supplied)

9 TECHNICAL DATA

Rated Voltage

230-240V

Rated frequency

50Hz

Rated power

600W

Protection class

II

Tank capacity

0.8l

Max. rotation speed

30.000min

-1

Nozzle diameter

Ø 1.8mm

Hose length

1.5m

Maximum nozzle flow rate

380 ml/min

Weight

2.05kg

10 NOISE

Noise values measured according to relevant standard. (K = 3)

Acoustic pressure level LpA

81 dB(A)

Acoustic power level LwA

92 dB(A)

ATTENTION! The sound power level may exceed 85 dB(A), in this case
individual hearing protection shall be worn.

aw (Vibration)

1.6 m/s²

K = 1.5 m/s²