Cleaning and maintenance, Technical data, Noise – Powerplus POW754 PAINT SPRAY GUN 600W EN User Manual
Page 7: Pow754 en, 8cleaning and maintenance, 9 technical data, 10 noise
POW754
EN
Copyright © 2014 VARO
P a g e
| 7
www.varo.com
Measure the amount of time it takes for the cup to empty back into the can. The table below
shows recommended times for different types of material.
VISCOSITY TABLE
Varnishes, synthetic resin primers
Undiluted
– 30
Synthetic resin paints, clear varnishes
15-30
Acrylic paints
20-30
Wood preservative, pesticides, oils
Undiluted (max.30)
Aluminium paints
15-30
Disinfectants, cleaning agents, polishes
Undiluted (max.30)
8
CLEANING AND MAINTENANCE
Always remember to disconnect from the mains supply before cleaning the
spray gun or paint container.
It is very important to clean your spray gun thoroughly after use. Failure to do so may render
the spray gun useless. Clean using suitable thinners, turpentine or water, depending on the
product used for spraying. Never immerse the spray gun in any fluid. Use tinners, turpentine or
water with a cloth to clean the exterior of the spray gun and a small brush for the spray
assembly. If the cylinder hole becomes blocked, use a suitable cylinder cleaning needle (not
supplied)
9 TECHNICAL DATA
Rated Voltage
230-240V
Rated frequency
50Hz
Rated power
600W
Protection class
II
Tank capacity
0.8l
Max. rotation speed
30.000min
-1
Nozzle diameter
Ø 1.8mm
Hose length
1.5m
Maximum nozzle flow rate
380 ml/min
Weight
2.05kg
10 NOISE
Noise values measured according to relevant standard. (K = 3)
Acoustic pressure level LpA
81 dB(A)
Acoustic power level LwA
92 dB(A)
ATTENTION! The sound power level may exceed 85 dB(A), in this case
individual hearing protection shall be worn.
aw (Vibration)
1.6 m/s²
K = 1.5 m/s²