10 transporting and storage – Powerplus POW4820 POWER G ENERATOR 2000W DIGITAL EN User Manual
Page 15

POW4820-POW4830(SC)
EN
Copyright © 2010 VARO
P a g e
| 15
§ Reinstall the air filter parts after cleaning or replacing air filter element.
Fig 6
6.1
Maintenance cover
6.2
Air filter body
6.3
Air filter cover
6.4
Air filter element
9.3
Spark plug servicing
Please use high quality authentic spark plug.
To ensure proper engine operation, the spark plug must be properly gapped and free of
deposits.
§ Remove the bolts on the panel and the controlling panel.
Fig 18
18.1
Top maintenance cover
§ Take out the ignition coil rubber boot.
Fig 19
19.1
Grip
19.2
Spark plug wrench
19.3
Spark plug
§ Remove the spark plug with spark plug wrench.
Fig 20
20.1
Screwdriver
20.2
Spark plug wrench
20.3
Insert the screwdriver into the hole of the spark plug wrench and remover
the spark plug.
§ Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean
spark plug with a wire brush if it is to be reused.
§ Install the spark plug carefully by hand, to avoid cross-threading.
§ After a new spark plug has been seated by hand, it should be tightened ½ turn with a
wrench to compress its washer. If a used plug is being reinstalled, it should only require
⅛
to ¼ turns after being seated.
§ Reinstall the ignition coil rubber boot on the spark plug securely.
§ Reinstall the controlling panel.
The spark plug must be securely tightened. An improperly tightened plug
can become very hot and possibly damage the generator.
Never use a spark plug with an improper heat range.
Never use a spark plug wihtout damping resistance, or it will cause no AC
output.
output.
10 TRANSPORTING AND STORAGE
To prevent fuel spillage when transporting or during temporary storage, the generator
should be secured upright in its normal operating position, with the engine switch OFF.
The fuel cap vent lever is turned counter clockwise to the OFF position.
Allow the engine to cool well before turning the fuel cap vent lever to the OFF position.
10.1
When transporting generator:
§ Do not overfill the tank. (there should be no fuel in the filler neck)
§ Do not operate the generator while it is on a vehicle. Take the generator off the vehicle
and use it in a well ventilated place.