Fuel tank
and filter
Clean
n(3)
Fuel line
Check
Every 2 years (Replace if necessary) (3)
NOTE:
(1) Log hours of operation to determine proper maintenance.
(2) Service more frequently when used in dusty areas.
(3) These items should be serviced by an authorized dealer, unless the owner has the proper
tools and is mechanically proficient. See the Shop Manual.
Temperature (C°)
Time for changing oil (hour)
Recommended power factor
25
Normal
100%
30
18
95%
35
15
85%
40
12
70%
9.1
Changing oil
Drain the oil while the engine is still warm to assure rapid and complete draining.
Make sure to turn the engine switch and the fuel cap vent lever OFF before
draining.
§ Tilt the generator.
§ Loosen the screw.
§ Drain dirty oil completely.
§ Refill with the recommended oil, and check the oil level.
§ Reinstall the side maintenance cover and tighten the cover screw securely.
Engine oil capacity: 0.90l
Fig 4
4.1
Dipstick
4.2
Lowest oil Level allowed
Wash your hands with soap and water after handing used oil.
Please dispose of used motor oil in a manner that is compatible with the
environment. We suggest you take it in a sealed container to your local
service station for reclamation. Do not throw it in the trash or pour it on the
ground.
9.2
Air cleaner service
A dirty air cleaner will restrict air flow to the carburettor. To prevent carburettor malfunction,
service the air cleaner regularly. Service more frequently when operating the generator in
extremely dirty areas.
Do not use gasoline or low flash point solvents for cleaning. They are
flammable and explosive under certain conditions.
§ Loosen the cover screw and remove the maintenance cover.
§ Remove the screw under the air filter box.
§ Pull the air filter cover down 30mm and remove the air filter cover.
§ Remove the air filter iron clip and check the air filter element. Clean or replace the element
if necessary.