11 MAINTENANCE

Check every day the tightening of screws and nuts. Except the procedures described in this
manual, this tool needs no specific maintenance. The repair of the tool's inner components is
of the competence of specialists. The cleaning of plastic parts is done with a soft damp cloth
and a bit of mild soap. Never submerge the tool and do not use detergents, alcohol, spirit,
etc...For an in-depth cleaning, please consult the after-sales department.

WARNING: For maintenance and cleaning, always remove the plug from
the electric power supply. Never use water or other liquids to clean
electric parts.

12 TECHNICAL DATA

Rated voltage

– rated frequency

230V~ 50Hz

Rated Power

1600W

Protection class

class II

Weight

14.7kg

Cable length

2m

Chuck type

Hex

Impact Rate

1500 beats/min

13 NOISE

Noise emission values measured according to relevant standard. (K=1.5)

Acoustic pressure level LpA

83 dB(A)

Acoustic power level LwA

104 dB(A)

ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).

aw (Vibration):

18.6 m/s²

K = 1.5 m/s²

14 SERVICE DEPARTMENT

 Damaged switches must be replaced by our after-sales service department.
 If the connecting cable (or mains plug) is damaged, it must be replaced by a particular

connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).

15 STORAGE

 Thoroughly clean the whole machine and its accessories.
 Store it out of the reach of children, in a stable and secure position, in a cool and dry

place, avoid too high and too low temperatures.

 Protect it from exposure to direct sunlight. Keep it in the dark, if possible.

Don’t keep it in plastic bags to avoid humidity build-up.