beautypg.com

Cleaning and maintenance, Cleaning, Checking and replacing the carbon brushes – Powerplus POW1044 CIRCULAR SAW 1200W 185MM EN User Manual

Page 8: Lubrication, Technical data, Noise

background image

POW1044

EN

Copyright © 2013 VARO

P a g e

| 8

www.varo.com

9 CLEANING AND MAINTENANCE

Attention !Before performing any work on the equipment, pull the power
plug.

9.1

Cleaning

 Keep the ventilation slots of the machine clean to prevent overheating of the engine.
 Regularly clean the machine housing with a soft cloth, preferably after each use.
 Keep the ventilation slots free from dust and dirt.
 If the dirt does not come off use a soft cloth moistened with soapy water.

Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.

9.2

Checking and replacing the carbon brushes

The carbon brushes must be checked on a regular basis.
 In case of wear, replace both carbon brushes at the same time.
 After mounting new carbon brushes, let the machine run at no load for 15 minutes.

Use only the correct type of carbon brushes.

9.3

Lubrication

From time to time, apply a drop of oil to the thread of the lock screw .

10 TECHNICAL DATA

Rated voltage

230-240V

Rated frequency

50Hz

Rated power

1200W

Rotation speed

5500min

-1

Blade size

Ø 185 x Ø 20 x 1.4 (2,5) mm

Max cutting depth

65mm

Protection class

Class II

Maximum cutting capacity 90° - 90°

65mm

Maximum cutting capacity 45° - 90°

43mm

Number of teeth

24teeth

11 NOISE

Noise emission values measured according to relevant standard. (K=3)

Acoustic pressure level LpA

93 dB(A)

Acoustic power level LwA

104 dB(A)

ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).

aw (Vibration)

3.2 m/s²

K = 1.5 m/s²