Command 1 - channel setup, Appendix b: command tables – Casio EA-100 Command Tables User Manual
Page 2

72
Appendix B: Command Tables
Command 1 - CHANNEL SETUP
• Parameter values marked with asterisks are initial defaults.
• Channel = 1, 2 or 3, Operation = 5, 6
Trigger Threshold
Trigger
Edge
±
1
0
Set
input
voltage
*
0
Rising edge to rising edge
(*
1)
threshold
value
of
1
Falling edge to falling edge
–10
to
+10.
2
Rising edge to falling edge
3
Falling edge to rising edge
Channel
Operation
Post-Processing
Stat Samples
0
Clears all channels.
—
—
—
*
1
Channel
1
0
Clears the selected channel.
*
0
None
2
Channel 2
*
1
Auto-ID
1
d/dt
—
3
Channel 3
2
Voltage
(
±
10V)
2
d/dt, d /dt
3
Current
3
Statistics
2 to 512
Samples
used
4
Resistance
(*10)
5
Period
6
Frequency
7
Temperature (Celsius)
8
Temperature (Fahrenheit)
9
Light
1
0
Voltage (0 to 5V)
4
SONIC
Channel
0
Clears the SONIC channel.
*
0
None
* 1
Auto-ID
1
d/dt
—
2
Meters
2
d/dt, d /dt
3
Feet
3
Statistics
2 to 512
Samples
used
(*10)
5
DIG IN Channel
0
Clears the digital input channel.
* 1
Active
—
—
Number of Data Elements
Data
Elements
6
DIG
OUT
Channel
0
Clears the digital output channel.
0
to
15
Output data element value
1
to
22
Number of output data elements
(*
0)
—
(* 1)
2
2
2
2