13

GB/MT

Familiarise yourself with all local conditions,

e.g. water connections and shut-off device,
prior to installation.

Please read these directions for use through

carefully before installation and use. Keep all
safety instructions and directions for future use.

Installation

Installing the fitting

Shut off the main water supply to prevent water

leakage. Let the residual tap water drain off.

Install the fitting as shown in fig. A and B.

CAUTION! Do not bend the flexible hoses

9

and do not put them under tension. Otherwise
there is a danger of material damage.

Flushing the fitting

In order to remove any possible impurities, the

fitting has to be flushed before it is used for the
first time (fig. C):

Unscrew the mixing nozzle

12

and the spray

head.

Open the main water supply and the spray head

and allow the water to run for two minutes.

Then screw the mixing nozzle and the spray

head back on.

Operation

Bringing into use

Note: If the fitting has not been used for a long
period flush the pipes through thoroughly in order
to avoid stagnation and build-up of residues.

Open the main water supply.
Lift the adjusting lever

13

and swing it to the

right or left in order to regulate the speed or
temperature of the water flow.

Press the changeover switch

10

to set the

spray jet.

Press the changeover switch once more to set

to normal spray jet operation.

Check operation of the mixer. For this purpose

move the lever in all possible positions. Please
regularly check all connections to ensure that
they are tight.

Pull the spray head down slightly and then

forward out of the holder to have freedom of
movement of the spray head when in use.

Limiting the water temperature

The cartridge

19

in this faucet has a temperature

limiting function. This function is not activated
before leaving the factory (neutral setting).

CAUTION! Do not change the setting of the

temperature limit until you have installed the
fitting.

Shut off the main water supply.

Remove the red / blue hot / cold label

15

by

moving the lever

13

to the highest setting and

carefully push the label out from the inside with
a long flat object (see fig. D).

Release the lock screw

14

by turning it counter-

clockwise using the Hexagonal key

20

(see fig. D).

CAUTION! Do not take the screw out com-

pletely; just loosen it until the lever can be easily
taken off.

Take off the lever.
Loosen the cartridge cover ring

16

by hand

and remove the cartridge securing ring

17

using a pipe wrench.

Subsequently remove the adjusting ring

18

.

Please note: Make sure that the mobile part
of the cartridge is oriented horizontally. This
makes it easier to remove the adjusting ring.
Do not use a wrench. Do not release the car-
tridge nut and do not take off the cartridge.

Replace the dial in its original position in order

to reduce the hot water supply.

Place the dial as described in fig. E in order to

limit the hot water supply.

Once again place the dial in the neutral position

to end the hot water limitation.