Installation & Placement
Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector
Please consult the Instruction Leaflet supplied with the Ei100R for detailed
instructions as to how to correctly install and position the smoke detector
Important Precaution:
Do not install the actual smoke/heat
alarm itself in new or renovated
buildings until all work is completed
(including floor coverings) and the
building has been fully cleaned.
(Excessive dust and debris from
building work can contaminate the
smoke chamber and cause
problems, and it will also invalidate
the guarantee). If it must be
installed, cover it completely,
particularly around the edges, with
a dust cover (eg. a plastic bag),
until all cleaning is finished..
Technical Specification
Sensor
Ionisation, uses electrically
charged ions that will react
to smoke particles
Sensitivity:
Complies with BS 5446 Part 1:
2000
Source:
Americium 241
Airspeed:
Essentially immune to the effect
of airspeed.
Button Test:
Simulates the effect of smoke and
checks chamber, electronics and
horn.
Supply Voltage:
10.2 to 14 volts
Alarm:
Piezoelectric-horn
in unit
Alarm Sound Output:
85dB (minimum) at 3m
Temperature Range:
0 to 40°C
Humidity Range:
0% to 90% Relative Humidity
Fixing:
Screw fixings supplied
Plastic material:
UL94HB flame retardant
Dimensions:
140x120x45 mm
Weight:
150 gram
Warranty:
5 year (limited) warranty
Approvals:
Kitemarked to BS5446-1:2000, CE
Approved
Specifications are subject to change