beautypg.com

Troubleshooting, Accessories and other features, Product guarantee – Ei Electronics EI 170 User Manual

Page 3

background image

power the system in standby for a week followed by at least 4
minutes alarm. When the mains fails, the green light is extin-
guished and the red light flashes rapidly on the control panel to
indicate it is on battery power. If the battery is starting to be
fully depleted the red light will go off to indicate the control
panel is totally unpowered. The battery will last 5 years in nor-
mal use provided it is not exposed to extremes of temperature
for prolonged periods, or fully discharged/charged a large
number of times.

We recommend that the functioning of the rechargeable

battery is checked at least yearly as follows:

(i) Ensure the control panel has been mains powered for at

least the previous 20 hours for the battery to charge.

(ii) Turn off the mains power to the control panel by unplug-

ging it or switching off the circuit at the distribution board.
Check that the green light goes off and the red light starts to
flash.

(iii) Press the control panel test button for 20 seconds and

check the strobe flashes brightly and that the pad vibrates
strongly. Check that the red light continues to flash while the
test button is pressed. (Cover the strobe light with card to stop
this dazzling you while looking for the red light). This red light
flashing indicates that the battery is satisfactory. If the red light
goes off, or if the strobe is weak, or if the vibration is weak, the
battery will need to be replaced. Contact the nearest address
in this leaflet for advice about getting a replacement.

3. Troubleshooting

If the units fail any of the tests after installation outlined

above, the system has probably been incorrectly wired and/or
all units are not connected. Check all wiring carefully. If the
green power lights on the smoke alarm and/or the control
panel are not on, check the wiring to the mains and that the
mains is not off (e.g. due to a tripped circuit breaker or fuse).
Check the power switch on the control panel is on.

The control panel monitors the wiring to the vibration pad

and the smoke alarm pattress for faults.

(i) If the vibration pad is removed or if its wiring is open cir-

cuit, the control panel will flash the strobe.

(ii) If the wiring to the smoke alarm pattress is disconnected,

open circuited or short circuited, the control panel will turn on
the vibration pad and the strobe light.

There are no user serviceable parts in this unit. If it is though

to be defective, it must be returned to the manufacturer for re-
pair or replacement (see “Product Guarantee” section).

4. Accessories and other Features

Control Panel “Aux. Output”

The auxiliary output turns on when the control panel is in

alarm and can supply up to 200 mA at 12 Volts (range 10 to 14
Volts). (Note: the positive terminal is the pin next to the
“Clock Input” socket). An Auxiliary Strobe

EI

178 is available

and is supplied with 10 m of cable and a suitable plug. It can be
located, for example, where it is readily seen during the day
(e.g. downstairs hallway). An extra Vibration Pad

EI

174 is

available with 2 m of cable and a plug for connecting it to the
auxiliary socket.

Control Panel “Clock Input” socket

A suitable alarm clock (with a 5 to 24 Volts AC or DC output -

electrically isolated from the mains supply) can be connected
to this input socket with a 3.5 mm mono jack plug. When the
alarm clock triggers, the vibration pad turns on to wake the

person, but the internal strobe or auxiliary output do not turn
on.This lets the user know it is a wake-up call and not a fire.
Therefore the user needs only one vibration pad under their
pillow or mattress.

Triggering Control Panel into Alarm Externally

A manual fire alarm switch (e.g. a glass break type) can be

used to get the control panel to turn on the vibration pad and
strobe light. This is done by connecting the red and yellow
wires, from the control panel, together, with the switch (or
volt-free relay isolated contacts). The wires from the switch
can be connected into the circuit at the pattress terminals.

Note: This does not cause the smoke alarm to sound.

Adding an

EI

158 Smoke Alarm Pattress with relay

to the system

The

EI

158CS/158P Pattress is used where volt-free relay

contacts are required to signal to other equipment when one of
the smoke alarms sense fire. For example the relay can be
used to signal to a warden call system, or to turn on lights.

If there are more than two smoke alarms in the system the

first smoke alarm can be mounted on the opto-isolator pat-
tress

EI

172 as described above. The second smoke alarm, in-

terconnected to the first, can be mounted on the relay pattress

EI

158CS /

EI

158CSR or

EI

158P /

EI

158PR. When any

smoke alarm senses fire the

EI

172 pattress will signal the

control panel into alarm and the

EI

158 pattress will switch its

relay contacts. Note: If both an

EI

172 and an

EI

158 are being

used only 6 smoke alarms may be interconnected together on
the system.

Power Requirements

The typical currents at 230 VAC are

·

Standby

10 mA

·

Alarm

50 mA

5. Product Guarantee

Ei Electronics

guarantees this system for one year from the

date of purchase against any defects that are due to faulty ma-
terials or workmanship. This guarantee only applies to normal
conditions of use and service, and does not include damage
resulting from accident, neglect, misuse, unauthorised dis-
mantling, or contamination howsoever caused. This guaran-
tee excludes incidental and consequential damage. If this
system should become defective within the guarantee period,
it must be returned to the nearest address in this leaflet. It must
be carefully packaged with the power switch on the control
panel in the off position, and with the problem clearly stated
along with proof of the date of purchase. We shall at our dis-
cretion repair or replace the unit. Do not interfere with the sys-
tem or attempt to tamper with it. This will invalidate the
guarantee, but more importantly may expose the user to
shock or fire hazards.

This guarantee is in addition to your statutory rights as a con-

sumer.

Manufactured by

Ei Electronics.

Shannon, Co. Clare Ireland.

© 2001