Initial operation – Parkside PDMS A1 User Manual
Page 30

27
PDMS A1
GB
Initial operation
NOTE
►
The grinder may only be operated on 
cleaned, oil-atomised compressed air and 
may not exceed the maximum operating 
pressure of 6.3 bar at the appliance. The 
compressor must be fi tted with a pressure 
reducer to regulate the working pressure.
►
Wind the Tefl on tape supplied around all 
threaded connectors.
♦
Connect the appliance to a suitable compressed 
air source.
♦
First screw the 1/4“ threaded nipple onto 
the mini compressed air oiler 1/4“ threaded 
connector . 
♦
Then fi ll the mini compressed air oiler with 
1-2 drops of special compressed air oil. To 
do this, undo the crosshead screw at the mini 
compressed air oiler oil fi ller opening 
and allow a few drops of oil to enter the oil 
fi ller opening with the help of the oil bottle 
included in delivery.
NOTE
►
A mist oiler continuously and optimally lubri-
cates the grinder as a preparation stage 
after the pressure reducer. A mist oiler adds 
fi ne drops of oil to air fl owing through the 
appliance and therefore guarantees regular 
lubrication.
♦
Now screw the 1/4“ threaded nipple onto 
the mini compressed air oiler 1/4“ female 
threaded connector .
♦
Now press the quick connector on the compressed 
air hose (not included in delivery) onto the Com-
pressed air connector plug . The connection 
locks automatically.
♦
Now connect the other end of the compressed 
air hose to the (fi lter) pressure reducer on the 
compressor.
Tool-changing
Always disconnect the grinder from the compressed 
air supply before changing tools.
Only ever use tools which are ready for use. 
Furthermore, you must ensure that the minimum 
clamping length of the shaft in the chuck is not 
fallen below.
♦
Using the spanners included in the accessories, 
hold the spindle and chuck fi rmly and open 
or close the chuck in the direction of the 
arrows (see Fig. 3).
Fig. 3
♦
Now insert one of the 10 diff erent whetstones .
NOTE
►
Please note the danger caused by mismatching 
the diameter of the grinding tool shaft and 
the chuck. Incorrectly-fi xed grinding tools can 
cause severe vibration - injury hazard!
♦
Ensure that the grinding tool is correctly fi xed, 
and carry out a trial run of 30 seconds in a 
safe area at idling speed.
OPEN
CLOSE
IB_43105_PDMSA1_LB2.indb 27
IB_43105_PDMSA1_LB2.indb 27
14.05.14 11:16
14.05.14 11:16