RF Visual Indicator: On Transmission, Amber LED lights

continuously for 1.5 to 3.5 seconds while messages are being

transmitted.

Size of System: A maximum number of 12 units can com-

municate together on one system (however the range is like-

ly to be the limiting factor in many cases)

Communication: All units will communicate together as

shipped. After a unit has been house coded it will only commu-

nicate with other units house coded at the same time. House

coding is essential to prevent false alarms from

neighbouring systems.

Entering House Code Mode: Pressing and holding the

House Code switch until the amber light comes on and then

releasing puts the smoke alarm into house code mode.

House Code Mode: The alarm transmits and receives spe-

cific codes. The amber light flashes once every 5 seconds for

each unit’s code it memorises (including itself).

Clearing House Codes: The house codes memorised can be

deleted (i.e. the smoke alarms can be uncoded) by pressing

and holding the House Code switch on for about 6 seconds.

The amber light will come on and then flash slowly to indicate

the smoke alarm has been returned to the default factory set-

tings.