cur within the vicinity of air inlets.

Caution! To avoid damage to the

equipment and any possible

person injury resulting from this:

• Do not work with damaged or incom-

plete equipment, or with equipment

that has been converted without the

approval of the manufacturer. Before

initial operation, have a specialist

check that the required electrical pro-

tection measures are in place.

• Never operate the pressure washer

if the power supply cable or other im-

portant parts, such as the high-pres-

sure hose or the gun, are damaged.

• Protect the pressure washer from frost

and dry running.

• Use only original accessories and do

not carry out conversion work on the

equipment.

• Please read the notes in the operating

instructions on the topic of “mainte-

nance and cleaning”. Any measures

above and beyond these, particularly

opening the equipment, are to be car-

ried out by an electrician. In the case

of repairs, always contact our service

centre.

• The washer was designed for opera-

tion with a neutral detergent based on

a biologically decomposable anionic

tenside. Other detergents or chemical

substances could impair the safety of

the washer and damage it.

• If you come into contact with cleaning

agents, rinse with plenty of clean wa-

ter.

• Water that has passed through a

backflow preventer is classified as un-

drinkable.

• High-pressure hoses, fittings and

couplings are important for machine

safety. Use only high-pressure hoses,

fittings and couplings recommended

by the manufacturer.

• To ensure machine safety, use only

original replacement parts from the

manufacturer or replacement parts

authorised by the manufacturer.

Electrical safety:

Caution: to avoid accidents and

injuries from electric shocks:

• The plug and socket of an extension

cable must be water-tight!

Unsuitable extension cables can

be dangerous as people can be

harmed by an electric shock!

• Protect the electric plug connections

against moisture.

• If there is a risk of flooding, fix the

plug connections in an area that is

safe from flooding.

• Ensure that the mains voltage match-

es the specifications on the rating

plate.

• The electrical installation shall be ac-

cording to national wiring rules.

• Connection to the mains must be car-

ried out by an experienced electrician

and meet the requirements of IEC

60364-1.

• The device must only be connected to

a mains socket via a residual-current

circuit breaker (RCD) with a rated

leakage current of not more than

30 mA. Fuse: at least 6 ampere.

• Before each use, check the equip-

ment, cable and plug for damage.

• If the power cable for this equipment