20101-2-0806

FBB4 Blower Installation

Attention: Install blower assembly before connecting gas inlet

supply line.

Note: Junction box on right side of fireplace must be pre-

wired at time of fireplace installation for use with blower

assembly. It is recommended that an ON/OFF wall switch

be installed that will activate the power supply to the

furnace by a qualified electrician. See page 26 for junction

box wiring instructions

1. If installed, turn OFF gas supply to fireplace.
2. If applicable, turn OFF electric supply to fireplace.
3. Lower bottom louver on fireplace.

Attention: If installed, do not damage gas inlet supply line when

blower assembly is inserted into fireplace. If necessary, removal

of the gas inlet supply line may be necessary.

4. Insert blower assembly into interior, bottom of fireplace. Position

blower assembly behind gas valve, align notch on back of

blower assembly with center screw on fireplace back and push

blower assembly against fireplace back. The blower wheel must

be centered with the back wall of the fireplace. Place blower

assembly against the back wall. The magnets on the back and

bottom of blower assembly will sufficiently hold blower assembly

in place.

5. Position speed control box to the right of gas valve. Attach speed

control box to bottom of fireplace. The magnets on the bottom

of speed control will sufficiently hold the speed control box in

place.

6. With base (flush face) of fan control switch facing upward, insert

base flanges of fan control switch under the mounting tabs on

valve bracket. The base (flush face) of fan control switch must

be in contract with bottom of the firebox.

7. Insert power cord plug into junction box.
8. Close bottom louver on fireplace.

Note: This blower is equipped with a heat activated fan control

switch. Fan will operate when the fireplace warms up, and will

turn off when the fireplace cools down.

9. Installation of FBB4 optional variable speed blower assembly

is completed.

Figure 19

VALVE BRACKET

FAN SWITCH

FAN KIT

SPEED CONTROL

JUNCTION BOX

SWITCH HOLDER

(TOP OF VALVE BRACKET)

SEE NOTE

OPTIONAL BLOWER

I N S T A L L AT I O N I S

I N T E N D E D F O R

LOUVERED MODELS

ONLY.

OPTIONAL VARIABLE SPEED BLOWER INSTALLATION INSTRUCTIONS

This manual is related to the following products: