Warning:

Never use needles, wires, or similar cylindrical objects to

clean the pilot to avoid damaging the calibrated ruby that

controls the gas flow.

Cleaning and Pilot Maintenance

Oxygen Depletion Sensor Pilot (Figure 17)

When the pilot has a large yellow tip flame, clean the Oxygen

Depletion Sensor as follows:
1. Clean the ODS pilot by loosening nut B from the pilot tubing.

When this procedure is required, grasp nut A with an open end

wrench.

2. Blow air pressure through the holes indicated by the arrows.

This will blow out foreign materials such as dust, lint and

spider webs. Tighten nut B also by grasping nut A.

Label all wires prior to disconnection when servicing controls.

Wiring errors can cause improper and dangerous operation. Verify

proper operation after servicing.
Millivolt thermopile is self powered, gas valve does not require

110 volts. Maximum length of 20 feet of 16 AWG to conductor

wires is to be used with all optional switches.
Use the two leads (Red and Green) to attach optional

components.
Check 750 Millivolt System Operation

Millivolt system and all individual components may be checked

with a millivolt meter 0-1000 MV range.
Remote Receiver

Use the following steps to place the remote receiver adjacent to

the gas valve.

Attention: The remote receiver bracket is not used in this

installation.

1. The remote receiver can not be placed behind the gas valve

and burner assembly.

2. When facing the appliance, the remote receiver must be placed

to the right of the gas valve.

Install remote control receiver behind bottom louver.
Refer to remote control installation and operating instructions for

more details on remote control.

Keep the control compartment, logs and burner area surrounding

the logs clean by vacuuming or brushing area at least twice a

year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY

WHEN COOL.
Always turn off gas to the pilot before cleaning. For relighting,

refer to lighting instructions located on the rating plate of the

log set.

Never obstruct the flow of the combustion and ventilation air. Keep

the front of the fireplace clear of all obstacles and materials.
Leave at least 36" clearance from the front of the fireplace.
Screens should be closed during operation.

Figure 18

REMOTE/OFF/ON SWITCH

A DISTANCE/FERME/OUVERT

INTERRUPTEUR

IF ANY OF THE ORIGINAL WIRE

AS SUPPLIED WITH THIS UNIT

MUST BE REPLACED, IT MUST BE

REPLACED WITH NUMBER 18, 150°C

WIRE OR ITS EQUIVALENT.

SI UN DES FILS ELECTRIQUES

ORIGINAUX, VENANT DU FABRICANT

AVEC CETTE UNITE, DOIT ETRE

REMPLACE, VOUS DEVEZ LE

REMPLACER AVEC UN FIL

ELECTRIQUE DE NUMERO 18,

150

°

C DU L'EQUIVALENT.

THERMOPILE

GAS VALVE

THERMOCOUPLE

(NATURAL)

OFF

ON

REMOTE

(OPTIONAL) REMOTE CONTROL RECEIVER

(FACULTATIVE) CONTROLE E DISTANCE

DU RECEPTEUR

(OPTIONAL) WALL SWITCH

INTERRUPTEUR MURAL

(FACULTATIVE)

(OPTIONAL) THERMOSTAT

(FACULATIVE) THERMOSTAT

WIRING DIAGRAM

GAS VALVE

VALVE DE GAZ

REMOTE/OFF/ON SWITCH

A DISTANCE/OUVERT/

FERME INTERRUPTEUR

REMOTE CONTROL RECEIVER/

THERMOSTAT/ CONTROLE E

DISTANCE DU RECEPTEUR

H

N

This manual is related to the following products: