7

Overall dimensions

Width:

615,5 mm (front edge)

580 mm (rear edge)

Depth:

510 mm

Cut out dimensions

Width:

550 mm

Depth:

470 mm

Supply connections

Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner

Electric:
230-240V 50Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Aeration adjustment none

Instructions for the Installer

Engineers technical data

APPLIANCE CLASS:

3

APPLIANCE CATEGORY:

II2H3+

APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar

Ignition HT Spark
Spark Generator

Ispra Control's BF 50046

230-240V 0.6 YA T 120

Spark Gap

Fixed

Semi-rapid Burner
Heat Input

1.9 kW (6483 BTU/HR)

Rapid Burner
Heat Input

2.9 kW Natural Gas (9895 BTU/HR)

2.7 kW L.P.G. (9212 BTU/HR)

Auxiliary Burner
Heat Input

1.0 kW (3412 BTU/HR)

BURNER

RAPID

SEMI-RAPID

AUXILIARY

(large)

(medium)

(small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

NOMINAL THERMAL
POWER kW

2.9

0.65

1.9

0.45

1.0

0.33

NOMINAL FLOW
RATE m

3

/h

0.276

0.062

0.181

0.043

0.095

0.031

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

NOMINAL THERMAL
POWER kW

2.7

0.65

1.9

0.45

1.0

0.33

NOMINAL FLOW
RATE g/h

195

46.8

137

32.4

72

23.8

NOZZLE REFERENCE

86

40

71

32

50

28

NATURAL GAS

20 mbar

TYPE OF

GAS

CHARACTERISTICS

LPG GAS

28-30/37 mbar

1/100 mm

1/100 mm

VALUE = 49.92 MJ/Kg

VALUE = 37.78 MJ/m

3

Ws - 50.7 MJ/ m

3