Wiring diagram fault finding, Preliminary electrical systems check – Electrolux EGG 690 User Manual

Page 11

background image

11

A. IGNITOR SWITCH

B. IGNITOR UNIT

1

2

L

N

0

220
240

1

2

3

4

Wiring Diagram

Fault Finding

Preliminary Electrical Systems
Check

A. EARTH CONTINUITY CHECK - Appliance must be
electrically disconnected - meter set on

Ω (Ohms) x

1 scale and adjust zero if necessary.

a) Test leads from any appliance earth point to earth

pin on plug. Resistance should be less than 0.1
Ω (Ohm), check all earth wires for continuity and

all contacts are clean and tight.

B. INSULATION CHECK - Appliance electrically
disconnected, all switches ON.

a) meter set on

Ω (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block.
If meter reads «0» then there is a short circuit.

b) meter set on

Ω (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads
less than

∞ (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed
but no fault is indicated - a detailed continuity check
(i.e. by disconnecting and checking each
component) is required to trace the faulty component.
It is possible that a fault could occur as a result of
local burning/arcing but no fault could be found under
test. However a detailed visual inspection should
reveal evidence of burning around the fault.

START
Isolate appliance
and carry out:
A: Earth Continuity
check.

Has inlet fuse blown?

Carry out:
C: Polarity check.

Electricity supply
should now be
satisfactory.

Carry out:
D: Resistance to
Earth check.

Inlet wiring

faulty.

Rectify any

fault.

Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.

SOCKET

(face view)

PLUG (with cover
removed)

Earth Wire
Green/Yellow

Neutral Wire
Blue

Brown

Blue

Green
Yellow

Green
Yellow

Brown

Blue

( )

FUSE

( )

E

N

L

NO

YES

NO

YES