beautypg.com

Conversion from natural gas to lpg – Electrolux EGG 690 User Manual

Page 14

background image

14

Conversion from Natural Gas to
LPG

It is important to note that this model is designed for
use with natural gas but can be converted for use with
butane or propane gas providing the correct injectors
are fitted. The gas rate is adjusted to suit.

Method

• Ensure that the gas taps are in the 'OFF' position
• Isolate the hob from the electrical supply
• Remove all pan supports, burner caps, rings, crowns

and control knobs.

• With the aid of a 7mm box spanner the burner injectors

can then be unscrewed and replaced by the
appropriate LPG injectors.

To adjust the gas rate

With the aid of a thin bladed screwdriver completely
tighten down the by pass adjustment screw, see the
illustration under the heading ‘Commissioning’.
Upon completion affix the replacement rating plate on
the under side of the hob.

IMPORTANT
The replacement/conversion of the gas hob should only
be undertaken by a competent person.