A.2 measuring av, Current consumption, A.3 measuring rtcv – Epson S5U1C17801T1100 User Manual
Page 58
Appendix A HOW TO MEASURE CURRENT CONSUMPTION
52
EPSON
S5U1C17801T1100 HARDWARE MANUAL
(SOFTWARE EVALUATION TOOL FOR S1C17801)
until being reset.
When this circuit is actually used for your circuit, a proper pull-down resistance value must be selected because the
value affects the current consumption of total system.
(When R21 = 100KΩ IR21= 33 μA approx., and when R21 = 500KΩ R21 = 6.6 μA approx.)
If you do not use battery backup function, input RTCV
DD
to #STBY.
GPIO(P43)
RTC
OSC1
IVRAM
#STBY
R21
(10k )
S1C17801
Fig. A.2 #STBY Related Circuit
A.2 Measuring AV
DD
Current Consumption
Current consumed by the power supply for ADC (AV
DD
) can be measured by inserting an ammeter into JP5.
Note that sample software (software flow) for measuring the current consumption, the software referred in the
S1C17801 Current Consumption Measurement Application Note does not control the AV
DD
line.
A.3 Measuring RTCV
DD
Current Consumption
Current consumed by the power supply for IVRAM and RTC inside battery backup area (RTCV
DD
) can be
measured by inserting an ammeter into JP2.
When JP2 is measured between 2-3 pins, the voltage becomes 3.3V because RTCV
DD
is supplied from V
DD
generated by regulator. When JP2 is measured between 1-2 pins, on the other hand, the voltage becomes 3.0V
because RTCV
DD
is supplied from coin cell battery.
Note that sample software (software flow) for measuring the current consumption, the software referred in the
S1C17801 Current Consumption Measurement Application Note causes approximately 3 to 4 μA current to flow in
the RTCV
DD
line.