Your ECHO blower is designed to provide many hours of trouble free service. Regular scheduled maintenance will help
your blower achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take your
unit to an ECHO Service Dealer for maintenance. To help you decide whether you want to DO-IT-YOURSELF or have
the ECHO Dealer do it, each maintenance task has been graded.

Level 1 =

Easy to do. Most required tools come with unit.

Level 2 =

Moderate difficulty. Some specialized tools may be required.

Level 3 =

Experience required. Specialized tools are required.

ECHO offers REPOWER Maintenance Kits and Parts to make your maintenance job easier. Just below each task
heading are listed the various part numbers required for that task. See your ECHO dealer for these parts.

MAINTENANCE

INTERVALS

Component/System

Air Filter

Fuel Strainer

Fuel Line

Carburetor

Choke System

Cooling System

Muffler Spark Arrestor

Starter Rope

Fuel Leaks

Spark Plug

Ignition System

Screw/Bolts/Nuts

Maintenance

Procedure

Clean

Replace

Clean/Replace

Inspect

Inspect/Rebuild

Replace

Inspect/Clean/Replace

Inspect

Clean

Inspect

Clean

Inspect/Clean

Inspect

Repair

Clean

Replace

Clean/Replace

Inspect/Tighten/Replace

Every

Refuel

Before

Use

Daily or Every

4 hours

Three

Months

or 100

hours

Six

Months

or 300

hours

Yearly or

600 hours

• (1)

*Date Main-

tenance

Performed

No Maintenance required for coil and flywheel

IMPORTANT

Time intervals shown are maximum. Actual use and your experience will determine the frequency of required maintenance.

*Record dates of monthly and yearly inspections.
(1) Replacement will be required for Commercial use after 600 hours. For Consumer use, cleaning every 6 months is
required. Cleaning includes Rebuild Kits.