Three-phase 400 v, 2installation – Yaskawa Sigma-5 User Manual: Setup for Rotary Motors User Manual
Page 48

2.4 EMC Installation Conditions
2-27
2
Installation
Three-phase 400 V
• SGDV-D11A ( = 1R9, 3R5, 5R4, 8R4, 120, 170)
∗1. Products that have received CE marking are recommended for the 24 VDC power supply.
∗2. Install the following noise filter on the power line between the single-phase 200 V power
supply and the 24 VDC power supply.
Model number: FN2070-6/07 (SCHAFFNER)
∗3. For more information on this filter, refer to
Σ
-V Series Product Catalog. (KAEP S800000
42)
Symbol
Cable Name
Specification
c
I/O signal cable
Shield cable
d
Safety signal cable
Shield cable
e
Motor main circuit cable
Shield cable
f
Encoder cable
Shield cable
g
Control power cable
Shield cable
h
Main circuit cable
Shield cable
i
MECHATROLINK-II communication cable
Shield cable
U, V, W
L1, L2, L3
24 V, 0 V
CN2
CN1
PE
PE
1
2
3
6
5
CN8
4
CN6A, CN6B
7
Clamp
MECHATROLINK-II
controller
SERVOPACK
Brake Power
Supply
Safety unit
Encoder
Servomotor
Brake
Power supply:
Single-phase
200 VAC
Power supply:
Three-phase
400 VAC
Shield box
Clamp
Clamp
Core
Core
Clamp
Core
Core
Clamp
Noise
filter*
3
Core
Core
Surge
absorber
Surge
absorber
Core
Noise
filter*
2
Control
power
supply
24 VDC*
1
Clamp
Clamp
Clamp
One turn
One turn
Two turn
Two turn
One turn
Host