3 installation conditions for applicable standards – Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual
Page 26

2 Installation
2.1.3 Installation Conditions for Applicable Standards
2-4
• Other Locations
Do not mount the SERVOPACK and the converter in locations subject to high tem-
peratures, high humidity, dripping water, cutting oil, dust, iron filings, or radiation.
When storing the SERVOPACK and the converter with the power OFF, store it in an
environment with the following temperature and humidity:
• -20 to +85
°C, 90% RH or less. (with no condensation)
2.1.3 Installation Conditions for Applicable Standards
Applicable
Standards
UL508C
EN 50178, EN 55011 group1 classA, EN 61000-6-2, EN 61800-3,
EN 61800-5-1, EN 954-1, IEC 61508-1 to 4
Operating
Conditions
Overvoltage Category: III
Pollution degree: 2
Protection class: IP10
Installation
Conditions
UL Standard and Low Voltage Directive:
Satisfy the conditions outlined in AC SERVOPACK and Converter
Σ
-V
Series Safety Precautions For Use with Large-Capacity Models (manual
no.: TOBP C710829 07)
EMC Directive:
Certification is required after installation in the user’s machine under the
conditions outlined in 2.4 EMC Installation Conditions of this manual.