3 New and Modified Software Functions
YASKAWA AMERICA, INC. TM.V1000SW.029 Traverse Application V1000 Custom Software Supplement
11
Table 4 Additional Parameter Function Group
Table 5 Additional Parameter Function Number
Table 6 Additional Monitor Function Number
Table 7 Additional Monitors
Table 8 Additional Multi-Function Input Settings (H1-)
Function Group
Group Name
Digital Operator Display
P
Traverse Group
Traverse
Function No.
Description
P1
Disturbed Waveform Adjustment
Disturb WF Adj
Function No.
Description
U7
Traverse Monitors
Traverse
No.
MEMOBUS/
Modbus
Address
Name
Digital Operator
Display
Description
Analog
Output
Scaling
Unit
U7-02
0661h
Absolute Slave
Frequency
Slv Abs Freq
Base frequency reference summed with the anti-
phase dither.
10 V: Max
Frequency
(E1-04)
0.01 Hz
U7-03
0662h
Ripple Slave
Frequency
Slv Ripple Freq
Anti-phase dither summed with 50% of E1-04.
During reverse operation, displays a negative
frequency reference. The analog output will
remain positive for both run directions.
10 V: Max
Frequency
(E1-04)
0.01 Hz
U7-04
0663h
Base Slave
Frequency
Slv Base Freq
Base frequency reference (before disturbed
waveform is applied).
10 V: Max
Frequency
(E1-04)
0.01 Hz
No.
Description
80h
Disturbed WF Off
Open: Disturbed waveform enabled
Closed: Disturbed waveform disabled