Cable glands for asia, 8 cable gland selection – Yaskawa V1000 NEMA Type 4X/IP66 User Manual
Page 39

8 Cable Gland Selection
YASKAWA ELECTRIC TOBP C710606 35D YASKAWA AC Drive - V1000 NEMA Type 4X/IP66 Installation Manual
39
◆
Cable Glands for Asia
Yaskawa recommends the following SC cable glands but is not limited to SEIWA
ELECTRIC MFG Co., Ltd. for the V1000 NEMA Type 4X/IP66 drive. The SEIWA cable
gland is not readily available outside of Asia.
Table 20 Cable Glands for Drive Main Circuit Wiring
Voltage
Class
Model No.
CIMR-V
Conduit
Hole Diameter
mm
Cable Gland (Seiwa)
Input
Holes
Output
Holes
Option
Holes
Appropriate
Wiring
Diameter
mm
Product
Number
Tightening Torque
Nm
Body, Cap
Body,
Locknut
Single-
Phase
200 V
Class
BA0001G
22
22
22
10.5 to 12.5
SCL-14A
2.5 to 2.9
2.9 to 3.4
BA0002G
BA0003G
BA0006G
28
28
28
10.6 to 12
SC-4A
2.0 to 2.5
2.9 to 3.4
BA0010G
12.1 to 14
SC-4B
BA0012G
14.1 to 16
SC-4C
Three-
Phase
200 V
Class
2A0001G
22
22
22
10.5 to 12.5
SCL-14A
2.5 to 2.9
2.9 to 3.4
2A0002G
2A0004G
2A0006G
2A0008G
28
28
28
10.6 to 12
SC-4A
2.0 to 2.5
2.9 to 3.4
2A0010G
10.6 to 12
SC-4A
2A0012G
12.1 to 14
SC-4B
2A0018G
14.1 to 16
SC-4C
2A0020G
14.1 to 16
SC-4C
2A0030G
44
44
22
20.1 to 22
SC-6M
4.9 to 5.3
5.8 to 6.3
2A0040G
2A0056G
22.1 to 24.5
SC-6A
2A0069G
50
50
22
30 to 32
SCL-38A
3.4 to 3.9
4.9 to 5.3