8 cable gland selection, Cable glands for north america, Cable – Yaskawa V1000 NEMA Type 4X/IP66 User Manual
Page 36: Fer to, To sele, Ctions in, 8cable gland selection

36
YASKAWA ELECTRIC TOBP C710606 35D YASKAWA AC Drive - V1000 NEMA Type 4X/IP66 Installation Manual
8 Cable Gland Selection
8
Cable Gland Selection
◆
Cable Glands for North America
Specific cable glands and gland plate covers are not listed for North America.
and
list the enclosure conduit hole dimensions by drive model. Use these tables to
select cable glands or gland plate covers from a local supplier. Use UL approved cable
glands or gland cover plates with NEMA Type 4X, or IP66 integrity for all drive conduit
holes. Cable glands or gland plate covers are supplied by the customer.
■
V1000 Drive Model BA0001G to 4A0038G
Table 18 Conduit Hole Dimensions for Models BA0001G to 4A0038G
Voltage
Class
Drive Model
CIMR-V
Main Circuit
Control Circuit
Conduit Hole Diameter
mm (in)
Number
of Holes
Hole
Diameter
mm (in)
Total
Holes
Input
Holes
Output
Holes
Option
Holes
Single-Phase
200 V Class
BA0001G
22 (0.87)
22 (0.87)
22 (0.87)
1
22 (0.87)
3
BA0002G
BA0003G
BA0006G
28 (1.10)
28 (1.10)
28 (1.10)
1
BA0010G
BA0012G
Three-Phase
200 V Class
2A0001G
22 (0.87)
22 (0.87)
22 (0.87)
1
22 (0.87)
3
2A0002G
2A0004G
2A0006G
28 (1.10)
28 (1.10)
28 (1.10)
1
2A0010G
2A0012G
2A0020G
2A0030G
2A0040G
2A0056G
2A0069G