Heavy Duty
Table 7 Drive Watt Loss (Heavy Duty Rating)
200 V Single-PhaseClass
Model
CIMR-V BA
<1> Carrier frequency is set to 10 kHZ.
<2> Carrier frequency is set to 8 kHZ.
0001
0002
0003
0006
–
0010
0012
–
–
–
–
–
–
Rated Output Current
(A)
0.8 1.6 3.0 5.0 –
8.0 11.0 –
–
–
–
–
–
Generated
Heat Loss
Heatsink
Plate (W)
4.3 7.9 16.1 33.7 –
54.8 70.7 –
–
–
–
–
–
Internal (W) 7.4 8.9 11.5 16.8 –
25.9 34.1
–
–
–
–
–
–
Total (W) 11.7 16.8 27.6 50.5 –
80.7 104.8 –
–
–
–
–
–
200 V Three-Phase Class
Model
CIMR-V 2A
0001
0002
0004
0006
0008
0010
0012
0018
0020
0030
0040
0056
0069
Rated Output Current
(A)
0.8 1.6 3.0 5.0 6.9 8.0 11.0 14.0 17.5 25.0 33.0 47.0 60.0
Generated
Heat Loss
Heatsink
Plate (W)
4.3 7.9 16.1 27.4 48.7 54.8 70.7 92.6 110.5 213.3 239.5 347.6 473.9
Internal (W) 7.3 8.8 11.5 15.9 22.2 23.8 30.0 38.8 43.3 68.1 79.6 113.8 156.7
Total (W) 11.6 16.7 27.6 43.3 70.9 78.6 100.7 131.4 153.8 281.4 319.1 461.4 630.6
400 V Three-Phase Class
Model
CIMR-V 4A
0001
0002
0004
0005
–
–
0011
0018
0023
0031
0038
Rated Output Current
(A)
1.2 1.8 3.4 4.8 –
5.5 7.2 –
9.2 14.8 18.0 24.0 31.0
Generated
Heat Loss
Heatsink
Plate (W)
19.2 28.9 42.3 70.7 –
81.0 84.6 –
107.2 166.0 207.1 266.9 319.1
Internal (W) 11.4 14.9 17.9 26.2 –
30.7 32.9 –
41.5 61.7 75.0 102.1 115.4
Total (W) 30.6 43.8 60.2 96.9 – 111.7 117.5 –
148.7 227.7 282.1 369.0 434.5