3 conditions of acceptability – Yaskawa V1000 Finless Type User Manual
Page 10
3 Conditions of Acceptability
10
YASKAWA ELECTRIC TOBP C710606 21E YASKAWA AC Drive - V1000 Finless Installation Guide
Table 2 Recommended Heatsink Plate Thermal Compounds
Spread the required amount of thermal compound over the clean heatsink plate. Firmly press
the V1000 finless drive against the metal panel and hold it in place against the heatsink plate
for a few seconds. Wipe away any excess thermal compound from around the heatsink plate
edges.
Figure 3
Figure 4 Application of Thermal Compound
Note: Surface milling of the metal panel to within 0.05 mm (0.0019 in) flatness is required if use of
less thermal compound is desired.
Ensure the V1000 finless drive is firmly pressed against the metal panel for a few seconds to
ensure proper thermal transfer.
◆
Drive Heatsink Plate Installation Screw Size and Tightening
Torque
Screw size and torque specifications for heatsink plate installation screws that hold the drive
to a metal back panel are listed in
Table 3 Screw Size and Tightening Torque
Manufacturer
Type
Model
Required Amount
Shin-Etsu Chemical Inc.
Oil-based
compound
G746
100 to 250
μm (0.0039 to 0.0098 in)
(Varies in accordance with the flatness
of the metal panel.)
Dow Corning Toray Inc.
Silicone compound
for heat dissipation
SC4471CV
Voltage Class
Model
CIMR-V
Screw Size
Tightening Torque
Nxm (ft-lbf)
Single-Phase 200 V class
BA0001 ~ BA0012
M4
1.0 to 1.3 (0.74 to 0.96)
Metal panel
Thermal compound
Heatsink plate
Installation
screws
V1000 Finless