beautypg.com

Introduction – Yaskawa VS-616PC5/P5 Isolated 4-20mA Output Monitor Card CM-B2/P User Manual

Page 3

background image

Page 3

VS-616PC5/P5 Option Instruction Manual: Isolated Monitor Card CM-B2/P

INTRODUCTION

The Isolated Monitor Card CM-B2/P is mounted on the control board of a VS-616PC5 or P5 inverter,
and is used to convert the inverter’s analog monitor signals (0 to 10V) to an isolated configurable sig-
nal. This option card can be used on any of the VS-616PC5/P5 Series inverters. When purchasing an
option card, please specify the inverter model and code number.

Description

NAME

CODE NUMBER

FUNCTIONS

Isolated Monitor Card

CM-B2/P

73600-DO12X

Converts analog monitor signals (0 to 10V) to isolated signals
(0 to 10V, 4 to 20mA or 0 to 20mA).

CM-B2/P

7

3

6

0

0

-D

O

1

2

0

Grounding lead wire (connected
to terminal E (G) of inverter
control board

E

Terminal block TB1 for
isolated signal output

Analog monitor signals (0 to 10V) input
lead wire connected to terminals AM and
CM of inverter control board

Fig. 1 Isolated Monitor Card CM-B2/P

TB1

12

TB2

C

O

D

E

N

O

.

HRD1

Connector to inverter control
board (2CN)