V7 ethernet/ip option kit cm093 – Yaskawa CM093 User Manual
Page 9

Yaskawa Electric America, Inc. –
IG.V7.26, Page 9 of 11
Date: 05/24/2010 Rev: 10-05
V7 EtherNet/IP Option Kit
CM093
♦ Yaskawa Standard Speed/Torque Input Instance 151 (97h)
♦ Yaskawa Extended Speed/Torque Input Instance 155 (9Bh)
Input
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Instance
0h
Fault
Alarm
Drive Ready
Speed Agree
Fault Reset
Active
Running
Reverse
–
Running
Forward
1h
–
–
Terminal
P2-PC
Terminal
P1-PC
Terminal
MA~MC
Local Mode
Undervoltage
OPE Error
151 (97h)
2h
Output Frequency (Low Byte) [Scaled by parameter n152] [U-02]
3h
Output Frequency (High Byte) [Scaled by parameter n152] [U-02]
4h
Motor Torque (Low Byte) [0.1%] [U-08] [Available in OLV control mode only (n002 = 1)]
5h
Motor Torque (High Byte) [0.1%] [U-08] [Available in OLV control mode only (n002 = 1)]
6h
Output Current (Low Byte) [0.1A] [U-03]
7h
Output Current (High Byte) [0.1A] [U-03]
Input
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Instance
0h
Fault
Alarm
Drive Ready
Speed Agree
Fault Reset
Active
Running in
Rev
–
Running Fwd
1h
–
Terminal
P2-PC
Terminal
P1-PC
Terminal
MA~MC
Local Mode
Undervoltage
OPE Error
155 (9Bh)
2h
Output Frequency (Low Byte) [Scaled by parameter n152] [U-02]
3h
Output Frequency (High Byte) [Scaled by parameter n152] [U-02]
4h
Motor Torque (Low Byte) [0.1%] [U-08] [Available in OLV control mode only (n002 = 1)]
5h
Motor Torque (High Byte) [0.1%] [U-08] [Available in OLV control mode only (n002 = 1)]
6h ~ 7h
Reserved
8h
Frequency Reference (Low Byte) [Scaled by parameter n152] [U-01]
9h
Frequency Reference (High Byte) [Scaled by parameter n152] [U-01]
Ah
Output Frequency (Low Byte) [Scaled by parameter n152] [U-02]
Bh
Output Frequency (High Byte) [Scaled by parameter n152] [U-02]
Ch
Output Current (Low Byte) [0.1A] [U-03]
Dh
Output Current (High Byte) [0.1A] [U-03]
Eh ~ Fh
Reserved
10h
Main Circuit DC Voltage (Low Byte) [1VDC] [U-05]
11h
Main Circuit DC Voltage (High Byte) [1VDC] [U-05]
12h
Error Alarm 1 (Low Byte) [See Page 10 for a list of fault codes]
13h
Error Alarm 1 (High Byte) [See Page 10 for a list of fault codes]
14h
Error Alarm 2 (Low Byte) [See Page 10 for a list of fault codes]
15h
Error Alarm 2 (High Byte) [See Page 10 for a list of fault codes]
16h
Error Alarm 3 (Low Byte) [See Page 10 for a list of fault codes]
17h
Error Alarm 3 (High Byte) [See Page 10 for a list of fault codes]
18h ~ 1Fh
Reserved
1Ah
Digital Input Terminal Bit Field (Low Byte) [Terminals S1 ~ S7] [U-06]
1Bh
Digital Input Terminal Bit Field (High Byte) [Terminals S1 ~ S7] [U-06]
1Ch ~ 27h
Reserved