Yaskawa CM059 User Manual
Page 6
Yaskawa Electric America, Inc. –
www.yaskawa.com
IG.G5HHP.13 Page 6 of 10
Date: 11/06/06 Rev: 06-11
DeviceNet
DeviceNet
Name
Text
Limits
Class Instance Attribute
Control
Method
Name
Text
Limits
Class Instance Attribute
Control
Method
E1-10
Minimum Output Voltage
0.0 ~ 510.0
64
1
63
H4-06
AO Terminal 48 Bias
-10 ~ +10
64
1
98
E1-11
Mid Output Frequency B
0.0 ~ 150.0
64
1
64
H4-07
AO Terminal Signal Type Select
0 ~ 1
64
1
99
E1-12
Mid Output Voltage B
0.0 ~ 510.0
64
1
65
L1-01
Motor Overload Fault Select
0 ~ 1
64
1
9A
E1-13
Base Voltage
0.0 ~ 510.0
64
1
66
L1-02
Motor Overload Time Constant
0.1 ~ 5.0
64
1
9B
E2-01
Motor Rated Current
37.0 ~ 740.0
64
1
67
L2-01
Power Loss Detection Select
0 ~ 2
64
1
9C
E2-02
Motor Rated Slip
0.00 ~ 20.00
64
1
68
L2-02
Power Loss Ride-Thru Time
0.0 ~ 2.0
64
1
9D
E2-03
No-Load Current
0.0 ~ 2000.0
64
1
69
L2-03
Minimum Baseblock Time
0.0 ~ 25.5
64
1
9E
E2-04
Number of Motor Poles
2 ~ 48
64
1
6A
w/ PG
L2-04
Voltage Recovery Ramp Time
64
1
9F
E2-05
Motor Line-to-Line Resistance
0.000 ~ 65.000
64
1
6B
L2-05
Undervoltage Detection Level
64
1
A0
E2-06
Leakage Inductance
0.0 ~ 30.0
64
1
6C
OLV, FV
L2-06
KEB Decel Time
0.0 ~ 100.0
64
1
A1
E2-07
Saturation Coefficient 1
0.00 ~ 0.50
64
1
6D
OLV, FV
L3-01
Stall Prevention Accel Select
0 ~ 2
64
1
A2
E2-08
Saturation Coefficient 2
0.00 ~ 0.75
64
1
6E
OLV, FV
L3-02
Stall Prevention Accel Level
0 ~ 200
64
1
A3
E2-09
Mechanical Loss
0.0 ~ 10.0
64
1
6F
FV
L3-03
Stall Prevention Accel CHP Limit
0 ~ 100
64
1
A4
F1-01
Encoder (PG) PPR
0 ~ 60000
64
1
70
w/ PG
L3-04
Stall Prevention Decel Select
0 ~ 2
64
1
A5
F1-02
PG Feedback Loss Select
0 ~ 3
64
1
71
w/ PG
L3-05
Stall Prevention Run Select
0 ~ 2
64
1
A6
F1-03
PG Overspeed Select
0 ~ 3
64
1
72
w/ PG
L3-06
Stall Prevention Run Level
30 ~ 200
64
1
A7
F1-04
PG Deviation Select
0 ~ 3
64
1
73
w/ PG
L4-01
Speed Agree Level
0.0 ~ 150.0
64
1
A8
F1-05
PG Rotation Select
0 ~ 1
64
1
74
w/ PG
L4-02
Speed Agree Width
0.0 ~ 20.0
64
1
A9
F1-06
PG Output Monitor Ratio
1 ~ 132
64
1
75
w/ PG
L4-03
Speed Agree Detection Level
0.0 ~ 150.0
64
1
AA
F1-07
PG Integral Accel/Decel Select
0 ~ 1
64
1
76
V/f w/PG
L4-04
Speed Agree Detection Width
0.0 ~ 20.0
64
1
AB
F1-08
PG Overspeed Level
64
1
77
L4-05
Reference Loss Detection Select
-150.0 ~ +150.0 64
1
AC
F1-09
PG Overspeed Time
64
1
78
L5-01
Number of Auto Restarts Select
0 ~ 10
64
1
AD
F1-10
Speed Deviation Level
0 ~ 50
64
1
79
w/ PG
L5-02
Auto Restart Fault Select
0 ~ 1
64
1
AE
F1-11
Speed Deviation Delay Time
0.0 ~ 10.0
64
1
7A
w/ PG
L6-01
Torque Detection Select 1
0 ~ 4
64
1
AF
F1-12
PG Gear Teeth 1
0 ~ 1000
64
1
7B
V/f w/PG
L6-02
Torque Detection Level 1
0 ~ 300
64
1
B0
F1-13
PG Gear Teeth 2
0 ~ 1000
64
1
7C
V/f w/PG
L6-03
Torque Detection Time 1
0.0 ~ 10.0
64
1
B1
F1-14
PG Loss Detection Delay Time
0.0 ~ 10.0
64
1
7D
w/ PG
L6-04
Torque Detection Select 2
0 ~ 4
64
1
B2
H1-01
DI Terminal 11 Function Select
0 ~ 77h
64
1
7E
L6-05
Torque Detection Level 2
0 ~ 300
64
1
B3
H1-02
DI Terminal 12 Function Select
0 ~ 77h
64
1
7F
L6-06
Torque Detection Time 2
0.0 ~ 10.0
64
1
B4
H1-03
DI Terminal 13 Function Select
0 ~ 77h
64
1
80
L7-01
Forward Torque Limit
0 ~ 300
64
1
B5
OLV, FV
H1-04
DI Terminal 14 Function Select
0 ~ 77h
64
1
81
H1-05
DI Terminal 15 Function Select
0 ~ 77h
64
1
82
H1-06
DI Terminal 16 Function Select
0 ~ 77h
64
1
83
H2-01
DO Terminal 53-57 Function
0 ~ 37h
64
1
84
H2-02
DO Terminal 19-50 Function
0 ~ 37h
64
1
85
H2-03
DO Terminal 20-50 Function
0 ~ 37h
64
1
86
H3-01 AI Terminal 36 Signal Type Select
0 ~ 1
64
1
87
H3-02
AI Terminal 36 Gain
0 ~ 1000
64
1
88
H3-03
AI Terminal 36 Bias
-100 ~ +100
64
1
89
H3-04 AI Terminal 42 Signal Type Select
0 ~ 1
64
1
8A
H3-05
AI Terminal 42 Function Select
1 ~ 1Fh
64
1
8B
H3-06
AI Terminal 42 Gain
0 ~ 1000
64
1
8C
H3-07
AI Terminal 42 Bias
-100 ~ +100
64
1
8D
H3-08 AI Terminal 39 Signal Type Select
0 ~ 2
64
1
8E
H3-11
AI Terminal 39 Bias
-100 ~ +100
64
1
91
H3-12
AI Terminals Filter Time
0.00 ~ 2.00
64
1
92
H4-01
AO Terminal 45 Function Select
1 ~ 33h
64
1
93
H4-02
AO Terminal 45 Gain
0.00 ~ 2.50
64
1
94
H4-03
AO Terminal 45 Bias
-10 ~ +10
64
1
95
H4-04
AO Terminal 48 Function Select
1 ~ 33h
64
1
96
H4-05
AO Terminal 48 Gain
0.00 ~ 2.50
64
1
97