Refer to Sheet 1 for latest change.
DWG. NO. 02Y00025-0350
SHEET NO. 5 OF 6
R E L . 0 5 / 0 5 / 9 3
( m - df )
Table 5. Programming For DO-08 Outputs
Sn-27
Output
Setting
Type
Terminals
Output Contents
X X X 0
Fixed
TD5 - TD11
Overcurrent (oC)
Data
TD6 - TD11
Overvoltage (ou)
TD7 - TD11
Drive Overload (oL2)
TD8 - TD11
Fuse Blown (FU)
TD9 - TD11
not used
TD10 - TD11
Overheat (oH1)
TD1 - TD2
Zero-speed
TD3 - TD4
Speed at set frequency
X X X 1
Coded
TD5 - TD11
Bit 0
Output
TD6 - TD11
Coded Output
Bit 1
TD7 - TD11
(See Table 6)
Bit 2
TD8 - TD11
Bit 3
TD9 - TD11
Zero-speed
TD10 - TD11
Speed at set frequency
TD1 - TD2
Running
TD3 - TD4
Minor fault (HHP only)
B. GPD 503, GPD 575, or VCD 703: There are no adjustments to be made on the Digital Output option;
however, drive constant Sn-27 will have to be reprogrammed for the desired output signal content. See Table 5.
Table 4. Function of DO-08 Coded Output From GPD 515
Bits 3, 2, 1, 0
Output Contents
Bits 3, 2, 1, 0
Output Contents
0 0 0 0
No fault
1 0 0 0
External fault (EFxx)
0 0 0 1
Overcurrent (oC)
1 0 0 1
Drive hardware fault (CPFxx)
(including grounding)
1 0 1 0
Motor overload (oL1)
0 0 1 0
Overvoltage (ou)
1 0 1 1
not used
0 0 1 1
Drive overload (oL2)
1 1 0 0
Power loss (Uu) (including
0 1 0 0
Drive overheat (oH2)
momentary power loss)
0 1 0 1
not used
1 1 0 1
not used
0 1 1 0
Fuse blown (FU)
1 1 1 0
not used
0 1 1 1
not used
1 1 1 1
Cooling fan fault (FAn)