DWG. NO. 02Y00025-0350
SHEET NO. 4 OF 6
R E L . 0 5 / 0 5 / 9 3
( m - df )
Refer to Sheet 1 for latest change.
CAUTION
TO PREVENT ERRONEOUS OPERATION CAUSED BY NOISE
INTERFERENCE, USE SHEILDED CABLE FOR CONTROL
SIGNAL WIRING, AND LIMIT DISTANCE TO 50M (165 FEET) OR
LESS.
Route wires from the drive and connect to the peripheral device(s). Refer to "Electrical Installation" in the drive’s
technical manual for further information on use of shielded cable.
6. Adjustments.
A. GPD 515: There are no adjustments to be made on the Digital Output option; however, drive parameter
F6-01 will have to be reprogrammed for the desired output signal content. See Table 3.
Table 3. Programming For DO-08 Outputs
F6-01
Output
Setting
Type
Terminals
Output Contents
0
Fixed
TD5 - TD11
Overcurrent (SC, OC, GF)
Data
TD6 - TD11
Overvoltage (OV)
TD7 - TD11
Drive Overload (OL2)
TD8 - TD11
Fuse Blown (FU)
TD9 - TD11
not used
TD10 - TD11
Overheat (OH)
TD1 - TD2
Zero-speed
TD3 - TD4
Speed at set frequency
1
Coded
TD5 - TD11
Bit 0
Output
TD6 - TD11
Coded Output
Bit 1
TD7 - TD11
(See Table 4)
Bit 2
TD8 - TD11
Bit 3
TD9 - TD11
Zero-speed
TD10 - TD11
Speed at set frequency
TD1 - TD2
Running
TD3 - TD4
Minor fault
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- SI-ET3 (49 pages)
- MECHATROLINK-III (35 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)