beautypg.com

Daily operation – England's Stove Works 10-CDV User Manual

Page 16

background image

16

DAILY OPERATION

Refueling the Unit

Always press the “OFF” touch pad before refueling. This stove has a approximately 80-lb.

hopper, and should be refilled when the hopper level drops to three or four inches.

Note: The hopper lid will be warm; therefore, you should always use some type of hand protection.

NEVER place your hand near the auger while the stove is operating.

Note: Always ensure that all corn and pellet matter is cleared from the hopper lid gasket before

closing. Be sure to close and latch hopper securely before re-firing. Do not operate this unit
with the hopper lid open or unsecured.

Power Outage

If the power to the unit is interrupted for approximately three minutes or less, the unit will resume

operation when power is restored according to the following table:

Unit’s State Before Power Loss

State When Power Returns

ON Start-Up
Start-Up Start-Up
Shut-Down Shut-Down
OFF OFF

If the power is interrupted for more than (approximately) three minutes, the unit will be “OFF”

when power returns.

Important: Do NOT open the hopper lid or the door to the unit during power outage. Open

the closest outside door and a window to eliminate the home’s natural draft. Wait
for power to be restored and then press the “ON” button to re-start the unit, if
necessary.

NOTE: Remember:

1)

It is very important for the unit to be vented properly (see instructions on Outside Air),
as the natural draft is needed to clear the smoke from the stove.

2)

Do not open the hopper lid (or the unit’s door). This may cause fire to burn in the
hopper.

Fuel Outage

If your unit runs out of fuel, let the unit go through the complete Shut-Down cycle and then follow

the instructions for restarting the unit.

NOTE: DO NOT TRY TO RESTART THE UNIT HOT

. If the unit runs without pellets or corn,

after one hour the unit will shut down.

Combustion Blower Failure

If the Combustion (exhaust) Blower should fail on this unit, a Vacuum Shut-Down Switch will

automatically stop the auger. This will cause your stove to stop feeding fuel to the firepot, and the
unit will eventually stop completely. Check your power supply, including tripped breakers, etc. If the
blower has failed, you will need to contact Customer Service at (800) 245-6489.

NOTE: It is very important for the unit to be vented properly (see instructions on Outside Air), as the

natural draft is needed to clear the smoke from the stove.

This manual is related to the following products: