beautypg.com

Sel–1, Read, Copy – Yaskawa Copy Unit Model for GPD 503 User Manual

Page 5: Urfy, Nodat, Proer, Caper, D ifps, Noapl, Cser

background image

DWG. NO. 02Y00025-0415
SHEET NO. 5 OF 5
R E L . 1 0 / 2 8 / 9 6

( m - df )

Refer to Sheet 1 for latest change.

LIST OF COPY UNIT DISPLAYS

DISPLAY

DESCRIPTION

TROUBLESHOOTING

SEL–1

Memory selection display

n/a

rEAD

During read-out

n/a

CoPY

During write-in

n/a

urFY

During verification

n/a

noDAT

No constant data found at the entered

n/a

(NO DATA)

memory (memo) location.

ProEr

An attempt to read was made when READ

Turn off the switch on the Copy

(PROHIBIT

prohibit SW is turned on.

Unit to enable reading.

ERROR)

CAPEr

An attempt to copy or verify between

n/a

(CAPACITY

different Drive models was made.

ERROR)

d iFPS

Connected Drive has a different password

n/a

(DIFFERENT

from that of stored data.

PASSWORD)

EXMAPLE: Copy from GPD 503 to

GPD 333.

noAPL

READ, COPY or VRFY was attempted

Special setting for special PROM

(NOT

for special PROM Drive.

is needed.

APPLICABLE)

CSEr

An error occurred by checksum

Stored constants cannot be used.

(CHECKSUM

calculation for the stored data.

Try READ again.

E2PEr

Although an attempt to store

Use other memory No.

(E2 PROM

constants in the Copy Unit, they

E2 PROM fault in the Copy Unit.

ERROR)

cannot be stored correctly.

iFER

An error occurred in communication

Check connection between the

(I/F ERROR)

with the Drive.

Copy Unit and Drive.

CPYEr

Data could not be written in normally

Try COPY operation again.

(COPY

to the Drive in COPY operation.

ERROR)

CPF04

An attempt to write in constants to

Execute initialization of constants

(DRIVE

the Drive was made but they could not

in the Program mode.

CPF04 FAULT)

be written in normally at the Drive.

Drive constant memory element
(NVRAM, EPROM) fault. If the
same fault occurs again, replace
the Drive’s Control PCB.

This manual is related to the following products: