Plant overview, Led signals graphic display – SMA STP 8000TL-10 User Manual
Page 2
Green LED is on:
Operation
Green LED is flashing:
Waiting for sufficient irradiation
Red LED is on:
Disturbance: contact installer.
Blue LED is on:
Bluetooth communication is active. The inverter can communicate with other
SMA Bluetooth devices with identical NetID.
DANgER!
Electric shock caused by high voltage in the inverter
Do not open the inverter!
Even when no external voltage is present, there can still be high voltages in the inverter.
• Electrical installation, repair and modification may only be carried out by a trained
electrically skilled person:
WARNINg!
New safety concept
If the Sunny Tripower beeps, it has detected a fault in the PV array and short-circuited the
PV array. The PV plant is now in a safe state.
• On no account disconnect the Electronic Solar Switch or the DC connector.
• Contact your installer immediately to remedy the fault.
CAUTION!
Risk of burns through contact with the enclosure during operation
• Do not touch any parts of the inverter during operation except the lower lid and
display.
The inverter energy and/or power is shown as a graph on the
display. The daily graph is displayed by default. The right-hand
flashing bar of the graph represents the current hour. If the inverter
does not feed any current to the electricity grid over a longer
period of time (e.g. during the hours of darkness or if the PV
modules are covered with snow), a gap is inserted into the chart.
The bar for the current hour is updated automatically every five
seconds.
After four seconds, the bar goes off for one second and then
displays the current value.
The power and energy of the inverter are displayed in three fields: Power, Day and Total. The
display is updated every five seconds.
Power
The power that the inverter is currently feeding into the electricity grid.
Day
The energy fed into the electricity grid on this particular day. This equals
the energy generated from the inverter's start-up in the morning to the
current time.
Total
The total energy that the inverter has fed into the electricity grid during its
entire operating time.
Serial number
Identification of the inverter by the type label
PRODUCT OVERVIEW
SAfETY PRECAUTIONS
gRAPh
POWER DISPLAY
MEASUREMENT ACCURACY
The display values may deviate from the actual values and must not be used for billing purposes. The
inverter's measured values are required for the operational control and to control the current to be
fed into the electricity grid. The inverter does not have a calibrated meter.
PLANT OVERVIEW
Current power
Daily energy
Total energy generated since the inverter was installed
Text line for displaying an event
Graphical display of the inverter
energy
/power
The display updates the values of your PV plant every five seconds.
You can operate the display by tapping the lower enclosure lid:
• Tapping the enclosure lid once: to activate the backlight, to
switch between the power range of the past 16 feed-in hours
and the energy yields of the past 16 days, to switch to the
next text line.
• Tapping the enclosure lid twice (valid as of firmware
version 2.31): the inverter shows, in succession, the firmware
version, the serial number and designation of the inverter,
the Bluetooth NetID, and the specified country standard and
display language.
Disturbance: contact installer
Switch open: no feed-in
Switch closed: feed-in
Output voltage /
current
of the line conductor shown below
Bluetooth connection with other devices
Input voltage/
current
Electricity grid event number
PV array event number
Inverter event number
Power reduction due to excessive temperature
• If the symbol is frequently displayed, contact your installer.
LED SIgNALS
gRAPhIC DISPLAY
A
B
Line conductor assignment
Switches between the inputs
A and B every 10 seconds
Graphic display
Electronic Solar Switch
LEDs