beautypg.com

Ctechnical data, C1 main technical characteristics – Electrolux 534074 User Manual

Page 10

background image

12

C

TECHNICAL DATA

C1

Main technical characteristics

MODEL

44” (208V)

44” (240V)

66” (208V)

66” (240V)

MAIN T

E

CHNICA

L D

A

T

A

Power supply

Electric

Electric

Electric

Electric

Power supply voltage

V

208 3PH

240 3PH

208 3PH

240 3PH

Frequency Hz

60

60

60

60

Max. power. absorbed with boiler
( rise 56 °C / 100 °F)

kW

44.7

44.7

45.0

45.0

Max. power. absorbed with boiler
( rise 39 °C / 70 °F)

kW

38.7

38.7

39.0

39.0

Max. power. absorbed with boiler
( rise 22 °C / 40 °F)

kW

32.7

32.7

33.0

33.0

Max. power. absorbed without boiler

kW

20.7

20.7

21.0

21.0

Max. current. absorbed with boiler
( rise 56 °C / 100 °F)

A

128.3

112.7

130.6

115.2

Max. current. absorbed with boiler
( rise 39 °C / 70 °F)

A

111.6

98.3

113.9

100.8

Max. current. absorbed with boiler
( rise 22 °C / 40 °F)

A

95.0

83.9

97.3

86.4

Max. current. absorbed without boiler

A

61.7

55.0

64.0

57.5

Supply water pressure

kPa/bar/PSI

150..700 / 1.5..7 /
22..102

150..700 / 1.5..7 /
22..102

150..700 / 1.5..7 /
22..102

150..700 / 1.5..7 /
22..102

Hot water supply temp. with boiler

**

( rise 56 °C / 100 °F)

°C/°F

27 / 80

27 / 80

27 / 80

27 / 80

Hot water supply temp. with boiler
( rise 39 °C / 70 °F)

°C/°F

44 / 110

44 / 110

44 / 110

44 / 110

Hot water supply temp. with boiler
( rise 22 °C / 40 °F)

°C/°F

60 / 140

60 / 140

60 / 140

60 / 140

Hot water supply temp. without boiler

°C/°F

90 / 194

90 / 194

90 / 194

90 / 194

Concentration of chlorides in water

ppm

< 20

< 20

< 20

< 20

Electric conductivity of water

μS/cm

< 400

< 400

< 400

< 400

Supply water hardness

°fH /°dH/
ppm CaCO

3

14 / 8 / 140

14 / 8 / 140

14 / 8 / 140

14 / 8 / 140

Rack loading/feed

RH machine
LH machine

From right to left
From left to right

From right to left
From left to right

From right to left
From left to right

From right to left
From left to right

No. speeds

2

2

2

2

Capacity speed 1

racks/h

100

100

100

100

Capacity speed 2

racks/h

200

200

200

200

Water consumption

l/h - gal/h

300 - 79.3

300 - 79.3

315 - 83.2

315 - 83.2

Equivalent sound pressure level Leq
(1)

dB(A)

< 70

< 70

< 70

< 70

Minimum Supply - Circuit Ampacity
Supply Terminal box ( Boiler ) (2)

A

67

58

67

58

Minimum Supply - Circuit Ampacity
Supply Terminal box ( Machine ) (2)

A

66

60

66

60

Maximum overcurrent protective device
Supply Terminal box ( Machine ) (2)

A

80

70

80

70

Net weight

lb/kg

1012 / 459

1012 / 459

1268 / 575

1268 / 575

Shipping weight

lb/kg

-

-

-

-

Shipping width

lb/kg

-

-

-

-

Shipping height

lb/kg

-

-

-

-

Shipping depth

lb/kg

-

-

-

-

PR

E

W

A

S

H

tank capacity

l/gal

-

-

45/ 11.9

45/ 11.9

temperature

°C/°F

-

-

max 40 / 104

max 40 / 104

pump delivery

l/min - gal/min

-

-

180 - 57.5

180 - 57.5

pump power

kW

-

-

0.37

0.37

current absorbed by pump

A

-

-

2.5

2.5

tank heating element

kW

-

-

-

-

WA

S

H

tank capacity

l/gal

100/ 26.4

100/ 26.4

100/ 26.4

100/ 26.4

temperature

°C/°F

71..78 / 160..172

71..78 / 160..172

71..78 / 160..172

71..78 / 160..172

pump delivery

l/min - gal/min

450 - 118.9

450 - 118.9

450 - 118.9

450 - 118.9

pump power

kW

1.9

1.9

1.9

1.9

current absorbed by pumps

A

6.2

6.2

6.2

6.2

tank heating element

kW

9.0 + 9.0

9.0 + 9.0

9.0 + 9.0

9.0 + 9.0

This manual is related to the following products: