Installation

C

LEARANCES

TO

C

OMBUSTIBLES

- F

REESTANDING

:

When installing this unit on a combustible floor (for example linoleum, hardwood flooring) a non-

combustible hearth pad must be under the unit. The pad must extend at least the width of the appliance

[22” (558 mm)] and at least the depth of the appliance plus 6” (153 mm) in front of the appliance [29

3⁄4” (756 mm)].

Side wall to unit

- 6 inches (15 cm)

Back wall to unit

- 1 inches (2.5 cm)

Corner to unit

- 1 inches (2.5 cm)

Door front to edge of floor protection

- 6 inches (15 cm)

30"

(76 cm)

48"

(122 cm)

36"

(91cm)

��

���� ���

��

��� ���

��

��� ���

��

���� ���

���� ����

��

��

��

����

���

���

����� ����������

Figure 9: EF3 Freestanding Clearance to Combustibles.

Minimum Alcove width - 36 inches (91 cm)

Minimum Alcove height - 48 inches (122 cm)

Maximum Alcove depth - 30 inches (76 cm)

Figure 10: EF3 Freestanding Minimum Alcove Size.

C

LEARANCES

TO

C

OMBUSTIBLES

- F

IREPLACE

I

NSERT

:

10" (25.4 cm) Mantel

8"

(20.3 cm)

8"

(20.3 cm)

S

id

e

W

al

l

Floor Protection; Minimum 6" (15 cm) in front of door

Figure 11: EF3 Fireplace Insert Clearance to Combustibles.

Refer to Figure 11.
Side wall to unit

- 8 inches

(20.3 cm)

Mantel projection

- 10 inches (25.4 cm)

Mantel to top of unit - 8 inches

(20.3 cm)

Top facing to unit

- 8 inches

(20.3 cm)

Side facing to unit

- 6 inches

(15.2 cm)

Floor protection

- 6 inches

(15.2 cm)

on either side and to the front must be

protected by non-combustible material.

These dimensions are minimum clearances but it is

recommended that you ensure sufficient room for

servicing, routine cleaning and maintenance.