Wiring diagram – Elkay ERC8-1B/2B User Manual

Page 2

background image

96602C (Rev. D)

ERC8-1B/2B, TRC8-1B/2B

ITEM

NO.

PART NO.

1

2

3

4

5

6

7

8

9

10

11

12

13

14*

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

NS

NS

23027C

31513C

31513C

191550951550

31475C

20282C

70018C

70091C

70009C

66305C

50189C

66202C

66267C

35807C

35801C

35795C

30180C

30181C

30182C

50076C

100806740570

19037000

101516143550

66455C

23025C

70772C

23033C

23034C

23036C

23037C

23031C

23026C

23028C

ITEMIZED PARTS LIST

DESCRIPTION

*INCLUDES RELAY & OVERLOAD. IF UNDER

WARRANTY, REPLACE WITH SAME COMPRESSOR

USED IN ORIGINAL ASSEMBLY.

NOTE: All correspondence pertaining to any of the

above water cooler or orders for repair parts MUST

include model number and serial number of cooler, name

and part number of replacement part.

Cover - Electrical

Control - Cold

Control - freeze prot.

Fan Motor

Fan Blade

Fan Bracket

Fan Nut

Washer - Fan Blade

Screw - Motor Mounting

Condenser

Shroud

Drier

Heat Exchanger

Compressor serv Pak (115v)

Relay

Overload

Overload Spring

Terminal Cover

Bale Strap

Sound Dampner

Grommet

Clip - Compressor Mtg.

Stud - Compressor Mtg.

Evaporator Assy

Panel - Front

Drain Plug

Panel - Side Right Hand

Panel - Side left Hand

Air Deflector

Electrical Compartment

Bracket - Evap. Locating

Panel - Rear

Cover - Top

ITEM

NO.

PART NO.

ERC8-2B, TRC8-2B - 220/240V, 50 HZ

DESCRIPTION

4

13

14*

15

16

191555551550

66476C

35809C

35802C

35796C

Fan Motor

Heat Exchanger

Compressor Serv Pak

Relay

Overload

WIRING DIAGRAM

ELKAY MANUFACTURING COMPANY - 2222 CAMDEN COURT - OAK BROOK, IL 60523 - 630.574.8484

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

FREEZE PROTECT

THERMOSTAT

COLD CONTROL

THERMOSTAT

21 TO 23

20

27

15 TO 19

14

13

26

25

28

29

12

10,11

4 TO 9

24

31

30

1

2

3

INSTALLATION

1. It is important to insure proper ventilation. For remote installation

a minimum clearance of 6 inches (152 mm) to the front must be

maintained, 1 inch (25 mm) each side, 3 inches (76 mm) to the rear

above the unit. Wall grille EG-1 or EG-2 to be ysed when unit is

inserted into an enclosure. Install unit as close as possible to wall

grille a 6 inch (152 mm) clearance beyond the front of the wall

grille is required for adequate air circulation.

2. Water inlet is 1/4" (6 mm) O.D. tube. Contractor to supply

connections as required.

3. Connecting lines to be of copper, thoroughly flushed to remove all

foreign matter before being connected to cooler. If flushing does

not remove all particles, a water strainer should be installed in

supply line

4. Connect cooler to building supply line with a shut-off valve and

install a union connection between the valve and cooler

5. Electrical: Make sure power supply is identical in voltage, cycle,

and phase to that specified on cooler serial plate. Never wire

compressor directly to the power supply.

START-UP

1. Open supply line valve.

2. Purge air from all water lines by operating bubbler valve of

fountain to which cooler is connected. Steady stream assures all air

removed.

3. Rotate fan to insure proper clearance and free fan action.

4. Connect to electrical power.

TROUBLE SHOOTING & MAINTENANCE

Temperature Control: Factory set at 50°F (+/- 5°) under normal

conditions. For colder water, adjust screw on item no. 3 CW.

Ventilation: Cabinet louvers and condenser fins should be

periodically cleaned with brush, air hose or vacuum cleaner.

Excess dirt or poor ventilation can cause no cold water and

compressor cycling on the compressor overload prctector.

Lubrication: Motors are lifetime lubricated.