Model ei261enrc co alarm, Technical specification, System wiring – Ei Electronics Carbon Mo-noxide Alarm Ei261ENRC User Manual
Page 2

Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.
+353 61 471277
Fx.
+353 61 471053
Email.
Web:
www.eielectronics.com
E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice
.
Ei261ENRC DataSht RevA
Technical Specification
Sensor
Electrochemical sensor
Sensitivity:
Meets BS EN 50291:2001
Button Test:
Checks the electronics and horn
Fast CO Test Mode:
Alarm sounds and red indicator
flashes as soon as CO is detected
–
the rate of flash indicating the CO
level
Memory Feature
A
fter the unit has been in alarm, the red
indicator will flash every 40 seconds at a
rate indicating the CO level previously
detected. Pressing the “Test/Hush”
button will also cause the red indicator
to flash at a rate specific to the
previously sensed CO level.
Automatic Self-Test:
Horn beeps and amber fault light
flashes every 40 seconds if a sensor
fault is found
Supply Voltage:
230V AC, 50 Hz
Battery back up:
Rechargeable Lithium cells
Dimensions:
126 x 150 x 42 mm
Weight:
300g
Model
Ei261ENRC CO Alarm
Power-On Indicator:
Continuous green LED
Alarm:
Electronic Piezoelectric horn
Alarm Sound Output:
85dB(A) (minimum) at 3m
Alarm Status:
Red LED flashes and horn sounds
Normal Operating
Temperature Range:
-10
o
to +40
o
C
Humidity Range:
15% to 95% Relative Humidity
Interconnect:
Up to 12 interconnected
- Ei261ENRC/261DENRC CO alarm
-
Ei161RC/164RC/166RC smoke or
heat alarms
- Ei128RBU relay base
Use with optional control (see below)
Optional Controls:
-
Ei1529RC Control Switch
-
MCP401RC Manual Call Point
Fixing:
Easi-Fit mounting base
Plastic material:
UL94VO flame retardant
Guarantee:
5 year (limited)
Approvals:
Kitemarked to BSEN 50291:2001,
(License no. KM86596) and CE
certified
Specifications are subject to change
System Wiring
Wiring for Interconnected Alarms with optional Remote System Control Switch & Manual Call Point
Ensure correct wiring of the alarms and switches as mixing Live and Neutral will blow / damage interconnected units.