Electrical connections

The appliance is designed to be connected to 230-240 V

monophase electricity supply.

The connection must be carried out in compliance with

the laws and regulations in force.

Before the appliance is connected:

1) check that the main fuse and the domestic installation

can support the load (see the rating label);

2) check that the power supply is properly earthed in

compliance with the current rules;

3) check the socket or the double pole switch used for

the electrical connection can be easily reached with

the appliance built in the furniture unit.

The appliance is supplied with a connection cable provided

with a plug, able to support the load marked on the

identification plate. The plug has to be fitted in a proper

socket.

If connecting the appliance directly to the electric system,

it is necessary that you install a double pole switch

between the appliance and the electricity supply, with a

minimum gap of 3 mm. between the switch contacts

and of a type suitable for the required load in compliance

with the current rules.

WARNING: Servicing shall only be carried out

by authorised personnel.

Substitution of the nozzles

- Remove all pan supports, burner caps, rings and

crowns;

- With a tubular spanner no. 7 unscrew and remove

(see diagram) the nozzles substituting them with those

corresponding to the type of gas used (see Technical

data);

- Remount the parts carrying out the operations

described in reverse. Upon completion remove

existing gas type label and stick the relevant gas type

label near the gas supply pipe.

If the pressure of gas used is different (or variable) from

that foreseen an appropriate pressure regulator should

be installed on the entry tube. In case pressure regulators

for U-LPG are used these should conform to the

regulations in force.

Regulation of the minimum

To regulate the minimum:

- bring the tap to the minimum flame position.

- extract the knob.

- in case of conversion from natural gas to U-LPG, tightly

screw the by-pass screw (see diagram);

- when converting from U-LPG to natural gas unscrew

about ½ turn by-pass screw, until a regular small flame

is reached.

Finally check that by quickly turning the tap from the

maximum position to the minimum position the burner

is not extinguished; remount the parts carrying out

the operations described in reverse.

Adaptation to different types of gas

FO 0392

By pass screw

The connection cable has to be placed in order that, in

each part, it cannot reach a temperature 50 °C higher

than the room temperature.

The brown coloured phase cable (fitted in the terminal

block contact marked with "L") must always be connected

to the network phase.