beautypg.com

Important safety requirements, Instructions for the installer, Location – Electrolux EHG 65 User Manual

Page 6: Engineers technical data

background image

6

700 mm

400 mm

100 mm

400 mm

50 mm

55 mm

50 mm

650 mm

400 mm

400 mm

100 mm

50 mm

50 mm

55 mm

600 mm

FO 0812

FO 0813

Important safety requirements

Location

Choose a location free of draughts and open doors and

clear of combustible materials or other fire hazards such

as curtains, etc. The location should ensure convenience

of operation and service. Any adjacent wall surface

situated within 200mm from the edge of any hob burner

and above the height of the hob must be a suitable non-

combustible material for a height of 150 mm for the entire

depth and width of the cooker.

Any combustible material above the hotplate must be at

least 650 mm above the top of the hob and no

construction shall be within 450 mm above the top of the

burner.

A minimum distance of 100 mm. must be left between

the side edges of the hob and any adjacent cabinets or

walls.

FITTING THE GAS HOB

WITHOUT A COOKER HOOD ABOVE

FITTING THE GAS HOB

WITH A COOKER HOOD ABOVE

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid

35

Triple crown

42

Aeration adjustment none

SUPPLY CONNECTIONS
Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply

APPLIANCE GAS SUPPLY:

Natural gas 1.0 kPa - Universal LPG 2.75 kPa

Instructions for the Installer

Engineers technical data

OVERALL DIMENSIONS
Width:

580 mm.

Depth:

500 mm.

CUT OUT DIMENSIONS
Width:

550 mm.

Depth:

470 mm.

TYPE

NOZZLE

NOMINAL

NOMINAL

OF BURNER

MARKS

GAS

PRESSURE

1/100 mm CONSUMPTION

kPa

MJ/h

Triple Crown (wok)

1.57

13.00

Semi-rapid (medium)

1.11

6.80

1.00

Auxiliary (small)

0.89

3.80

Triple Crown (wok)

0.97

13.00

Semi-rapid (medium)

0.71

6.30

2.75

Auxiliary (small)

0.55

3.80

NATURAL

GAS

U-LPG

TYPE

OF GAS

This manual is related to the following products: