Triton Plus - Ported RS-422 Data - User Manual

15

Router Communication

Router Communication

You gain access to the router for communication purposes by connecting
the router’s serial port to your computer.

Serial Connection

Connection can by made trough the serial port(s) of the router; see also

Con-

nection Details on page 8

for connection details.

The communication parameters are configurable. Please refer to the pro-
tocol documentation of the appropriate communication/control protocol.

Example: The protocol parameters of the Triton Plus Compact routers are
as follows:

Bit rate 19200 bit/s

Data bits 8 bits

Stop bits 1

Parity: No parity

For further detail concerning this protocol, please refer to the following
manual: Compact Router Control Protocol.

The DB9 female connector for the serial port(s) of the router has the fol-
lowing pinout (

Table 9

):

Note

If the standard RS-232 cable specification (DCE) is followed:


A cable with Male+Male or Female+Female connectors at the cable ends is
used for Rx/Tx crossed connection.


A cable with Male+Female connectors at the cable ends is used for a straight
through connection.

Table 9. Serial Connection Pinout

Pin #

RS-232 Mode

1

Not in use

2

Tx

3

Rx

4

Not in use

5

GND

6

GND

7

RTS

8

CTS

9

Do Not Connect!