Triton Plus - Ported RS-422 Data - User Manual

LED Status

LED Status

The LED located at the front of the router indicates the status of the router.
At start-up, the LED will alternate between red (R) and green (G) every
500ms for about two seconds. After the start-up sequence the LED will
indicate the Alarm state of the router.

Alarm States

The LED can either be red (R), green (G), or have no light (N).

The LED state is described in

Table 8

below with twenty letters, each repre-

senting 100ms, which totals an alarm sequence of two seconds. The X indi-
cates that the LED keeps the color it has the moment the alarm sequence
begins (green or no light).

Table 8. LED Alarm States

Description

LED State

Alarm

Comment

Continuous Green Light

GGGGG GGGGG GGGGG GGGGG

No Alarm

Status OK

Long Red Blinking

RRRRR NNNNN RRRRR NNNNN

Power is too low

One Short Red Blink

RXXXX XXXXX XXXXX XXXXX

Power A failed

Only active if power alarm
DIP is set.

Two Short Red Blinks

XXXXX XXXXX RXRXX XXXXX

Power B failed